Performance Data Sheet - Watts Premier RO-Pure Installation, Operation And Maintenance Manual

Reverse osmosis (ro) water treatment system
Table of Contents

Advertisement

GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that
is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certifi ed for cyst reduction may be used on
disinfected water that may contain fi lterable cysts.
2. This system is acceptable for treatment of infl uent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in combination measured as N and is
certifi ed for nitrite/nitrate reduction only for water supplies with a pressure of 280 kPa (40 psig) or greater. If your water supply is under 40 psi Watts Premier
recomends the use of a RO booster pump for proper operation.
3. Operating Temperature:
4. Operating Water Pressure:
5. pH
6. No iron present in incoming feed water supply.
7. Hardness of more than 10 grains per gallon (170 ppm) may reduce RO membrane life expectancy.
8. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Sediment Pre-fi lter:
Carbon Pre-fi lter:
Final Carbon fi lter
R.O. Membrane:
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specifi ed in NSF/ANSI 58. This
system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or
less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free
chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined
chlorine) is not suffi cient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the Arsenic Facts section of the Performance Data
Sheet for further information.
Avg. In.
(mg/L)
Arsenic (Pentavalent)
.310
Barium Reduction
Cadmium Reduction
0.031
Chromium (Hexavalent)
0.30
Chromium (Trivalent)
0.30
Copper Reduction
Cysts
92,000#/ml
Fluoride Reduction
Lead Reduction
0.15
Nitrate
Nitrite
Nitrate + Nitrite
Perchlorate
0.14
Radium 226/228
25pCi/L
Selenium
94.85
TDS
741
Recovery - 15.77%
Depending on water chemistry, water temperature, and water pressure Watts Premier's R.O. Systems production and performance will vary.
Effi ciency rating means the percentage of the infl uent water to the system that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage. Recovery rating means the percentage of the infl uent water to the membrane portion
of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the
storage tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER'S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY
INFORMATION.
Phone: (623) 931-1977
1725 W. Williams Drive C-20
Phoenix, AZ 85027 USA
California Certifi cation # 07-1882
System conforms to NSF Standard 58 for specifi c claims.
Maximum: 100°F (40.5°C)
Maximum: 85 psi (6.0kg/cm2)
2 to 11
#105311
#105351
#105361
#105331
Avg. Eff.
% Reduction pH
(mg/L)
0.001
99.6%
9.2
0.08
99.0%
0.0004
98.0%
0.002
99.0%
0.001
99.0%
3.2
0.02
99.0%
3 #/ml
99.99%
8.7
0.19
97.0%
0.002
98.8%
27
3.8
86.0%
3.1
0.41
86.0%
30
4.2
86.0%
0.003
97.0%
5pCi/L
80.0%
<0.2
97.0%
22
97.0%
Fax: (623) 931-0191
Watts Premier Inc.
RO-Pure
Change time Frame
6 Months
6 Months
12 Months
2 to 5 years
Pressure
Max Eff.
7.24
50psi
7.64
50psi
7.49
50psi
0.0008
7.24
50psi
7.64
50psi
7.40
50psi
7.44
50psi
7.24
50psi
7.39
50psi
7.24
50psi
7.24
50psi
7.24
50psi
7.39
50psi
0.005 mg/L
7.24
50psi
5pCi/L
7.24
50psi
7.28
50psi
Daily Production Rate - 18.43 GPD
Page 17
Minimum: 40° (4.4°)
Minimum: 40 psi (2.8kg/cm2)
Cost
$12.50
$19.30
$19.30
$72.95
Inf. challenge
mg/L
concentration
mg/L
0.002
0.30±10%
0.12
10.0±10%
0.03±10%
0.004
0.03±10%
0.002
0.03±10%
0.04
3.0±10%
18
minimum 50,000/mL
0.3
8.0±10%
0.005
0.15±10%
4.3
27.0 ±10%
0.46
3.0 ±10%
4.8
30.0 ±10%
0.10±10%
25pCiL±10%
<0.2
0.10±10%
26.0
750±40mg/L
Effi ciency - 8.82%
Email: wpmail@watts.com
Max Allowable
concentration
mg/L
0.010 mg/L
2.0
0005
0.1
0.1
1.3
N/A
1.5
0.0107
10.0
1.0
10.0
0.006
5pCiL
0.05
187