Adapt-A-Valve Installation - Watts Premier RO-PURE Plus Installation, Operation And Maintenance Manual

Water supply
Table of Contents

Advertisement

Faucet Indicator Battery Replacement
1. Turn the handle on the storage tank ball valve to the
"off" position and lower faucet handle to "on" position.
2. Remove the faucet handle cover at the slot - (A).
Note: Water will dribble out of the spout, use caution
when handling the electronic components.
3. Slide the old battery out and replace with new battery.
Note: Once the battery is pushed into the clip a red and
blue light will flash indicating proper installation.
4. Replace cover assembly onto the faucet handle while
aligning the tab on the cover with the notch on
the faucets handle - (B).

Adapt-a-Valve Installation

Caution:
Water supply line to the system must be from the cold water supply line only.
Hot water will severely damage your system.
Verify contents prior to installation:
( 1 ) - Plastic Adapt-a-Valve with black collet
( 1 ) - Brass Adapter no washer
( 1 ) - Brass Adapter with black washer
( 1 ) - White rubber washer
*
White
Washer
A
3/8" Configuration
(With Brass Fittings)
* Insert White Washer
WARNING:
Do not use Teflon tape with the Adapt-a-Valve.
Step 5
Turn off the cold water supply to the faucet by turning the angle stop valve completely off.
Open cold water sink faucet to relieve pressure.
Choosing the configuration that fits your plumbing, attach the adapt-a-valve as illustrated in
Step 6
the four photos above.
TIPS:
Make sure that the black collet is installed in to the 1/4" opening on the Adapt-a-valve.
Don't forget to install the white compression washer with the 3/8" configuration.
Brass adapter (A) does not need to be tightened with a wrench, only finger tight.
Hot
Cold
Supply
Supply
A
1/2" Configuration
(Without Brass
Fittings)
Page 8
A
COVER
Black
Collet
White
Washer
Hot
Cold
Supply
Supply
B