Download Print this page

Fujitsu ASY10FSACW Service Manual

Wall mounted type
Hide thumbs Also See for ASY10FSACW:

Advertisement

SPLIT TYPE ROOM AIR
CONDITIONER
WALL MOUNTED TYPE
Indoor unit
ASY10FSACW
ASY12FSACW
CONTENTS
. . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . . . . . 3
. . . . . . . . . . . . . . . . . . . . . 6
INDOOR PCB CIRCUIT DIAGRAM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Outdoor unit
AOY10FSAC
AOY12FSAC
. . . . . 4
. . . . . . .8
. . . . . . . . .12

Advertisement

loading

Summary of Contents for Fujitsu ASY10FSACW

  • Page 1: Table Of Contents

    SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit Outdoor unit ASY10FSACW AOY10FSAC ASY12FSACW AOY12FSAC CONTENTS SPECIFICATIONS ..... . . 1 DIMENSIONS .
  • Page 2: Specifications

    COMPRESSOR AND REFRIGERANT ELECTRICAL DATA TYPE Cool Cool Hermetic type, Permanent split condenser INDOOR UNIT ASY12FSACW TYPE ASY10FSACW 2 pole, Single phase, OUTDOOR UNIT AOY10FSAC AOY12FSAC Induction motor COOLING CAPACITY 2.90 kW - 2.95 kW 3.45 kW - 3.50 kW 80230135...
  • Page 3: Dimensions

    DIMENSIONS Unit : mm INDOOR UNIT OUTDOOR UNIT 2008.05.29...
  • Page 4: Refrigerant System Diagram

    REFRIGERANT SYSTEM DIAGRAM ASY10FSACW / AOY10FSAC INDOOR UNIT Evaporator (Flare connection) (Flare connection) [ Connecting pipe ] Gas pipe (9.52 dia.) Liquid pipe (6.35 dia.) OUTDOOR UNIT (Flare connection) (Flare connection) 3-Way valve 2-Way valve (with charging port) Com- Condenser...
  • Page 5: Circuit Diagram

    CIRCUIT DIAGRAM INDOOR UNIT TRANSFORMER DISPLAY BOARD 3 4 5 6 7 THERMAL FUSE FAN MOTOR GRAY BLACK BLACK WHITE GRAY YELLOW WHITE BLUE WHITE CN103 CN104 CN102 CN101 WHITE WHITE POWER SUPPLY BOARD CONTROL BOARD WHITE WHITE CN105 WHITE W104 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10...
  • Page 6 C I R C U I T D I A G R A M Models : ASY10FSACW ASY12FSACW POWER TRANSFORMER CONTROLLER PCB ASSEMBLY ASY10FSACW : EZ-0980KWSE-C (GM-60089) ASY12FSACW : EZ-0980LWSE-C (GM-60090) POWER SUPPLY PCB MANUAL AUTO SWITCH FAN MOTOR (BLK)
  • Page 7: Disassembly Illustration

    D I S A S S E M B L Y I L L U S T R A T I O N – 12 –...
  • Page 8 Models : ASY10FSACW ASY10USACW ASY12FSACW ASY12USACW – 13 –...
  • Page 9 Model : AOY10FSAC – 14 –...
  • Page 10 Model : AOY12FSAC – 16 –...
  • Page 11: Parts List

    PARTS LIST INDOOR UNIT Part number Ref. Description Ref. Description Part number Decoration Plate-B 9307218040 Window (Receiver) 9305439027 Front Panel Assy 9305656394 Indicator Case 9305978014 Capacitor (Fan Motor) 9702105020 Lamp Cover 9305451012 Flow Control Panel-Z 9305443017 Control Box Cover 9305977017 Louver-A 9305415014 Power Supply PCB Assy...
  • Page 12 OUTDOOR UNIT Part number Ref. Description AOY10FSAC AOY12FSAC Emblem-Rear 9308468017 9308468017 Cabinet Front Panel, Plastic 9306386016 9306386016 Connector Cover (Cabinet) 9306119010 9306119010 Cabinet Rear Panel, Plastic 9306385019 9306385019 Base Assy, Painted 9306118020 9306118020 3-Way Valve 9310085011 9310085011 2-Way Valve 9310084014 9310084014 Dryer 9308440006...
  • Page 13 OUTDOOR UNIT (Continued) Part number Description Ref. AOY10FSAC AOY12FSAC Outlet Pipe (Cond.) 9308669001 9308666000 Bracket (Valve) 9306748036 9306748036 Terminal Gasket (Comp.) 9351121006 9351121006 Noise Insulation-F 9308464019 9308464019 Discharge Pipe 9308669001 9308666000 Tapping Screw (Special) 9305848010 9305848010 Screw (with Square Washer) 313681304205 313681304205 Terminal-3P 9306489014...
  • Page 14 ACCESSORIES Part number Name and Shape ASY10FSACW ASY12FSACW Wall hook bracket 9304358008 9304358008 Wall cap-B 313714296205 313714296205 Remote control 9307113048 9307113048 Remote control holder case 9305642014 9305642014 Battery (penlight) 0600185534 0600185534 Cloth tape 9308117007 9308117007 Tapping screw (big) (¿ 4 x 20)
  • Page 15 0103J1832...

This manual is also suitable for:

Aoy10fsacAsy12fsacwAoy12fsac