Automatic Registration Via B-Comm - Kaba access manager 92 30 Technical Manual

Table of Contents

Advertisement

Start-up
6.2

Automatic registration via B-COMM

70
Start-up of the access manager takes place largely automatically in connection with
the B-COMM communication software.
The device is preset at the factory for automatic registration via B-COMM.
System requirements
B-COMM communication software version 3.10 and higher.
Network with a working DHCP server.
Start-up procedure
1. Connect the access manager to the network and switch it on.
ð After booting, the device cyclically reports to the B-COMMs active in the net-
work.
ð In this status, the status LED lights up alternately 0.5 seconds in red and 0.5
seconds in green.
ð Once the device is found by B-COMM, the relevant data that identifies the
device will be queried.
ð If the device is not known, it will be entered in B-COMM under the
B-COMM Terminal Discovery client under BCTDS (Terminal Discovery
Stream).
2. If the device is to be managed via a B-COMM, it can be moved to the desired
stream and provided with the corresponding communication parameters.
ð After having assigned the device permanently to B-COMM, B-COMM first up-
dates the settings of the device and then makes a backup of the settings to-
gether with the "sop.ini" license file.
3. Transmitting specific parameters and master records to the device.
ð The terminal software is automatically restarted, after which the device is
ready for use.
ð The device now reports to the B-COMMs active in the network that registra-
tion has been carried out, after which the device will be removed again from
the BCTDS stream by the other B-COMMS.
ð This concludes the automatic registration via B-COMM.