Superior System; Reader - Kaba access manager 92 30 Technical Manual

Table of Contents

Advertisement

Design and function
4.2.2

Superior system

4.2.3

Reader

26
Communication with the superior system (host computer) takes place via the Ether-
net network.
The superior system serves for centralized management of authorizations, access and
room profiles, system configuration and alarm management.
The data collection of identification data is performed via external readers.
Up to 2 readers can be connected. The readers which are supported depend on the
device variant.
Kaba access manager 92 30 with connections for readers via Wiegand
Kaba access manager supports the connection of two readers via the Wiegand inter-
face.
Connection individually via Wiegand interface
Data collection of identification data
Control of optical and acoustic signal generators
Power supply via the access manager
Kaba access manager 92 30 with connections for registration units and readers
via RS-485
The Kaba access manager supports connection of two Kaba RFID registration units
via the coaxial cable.
Alternatively, up to 2 readers/subterminals can be connected via the RS-485 inter-
face.
Registration unit:
Connection individually via coaxial cable
Data collection of identification data
CardLink validation and update
Control of optical and acoustic signal generators
Keypad is supported
Power supply via the access manager
Readers via RS-485:
Connection via RS-485 partyline in bus or star wiring
Data collection of identification data
CardLink validation
Control of optical and acoustic signal generators
Keypad is supported
The inputs and outputs of subterminals can be used.
Power supply via the access manager possible