PARAMETER LIST
Function code
Function name
H105
PM motor rated current
H106
PM motor constant R
H107
PM motor constant Ld
H108
PM motor constant Lq
H109
PM motor constant Ke
H010(32-bits)
PM constant J
H111
Auto constant R
H112
Auto constant Ld
H113
Auto constant Lq
H116
PM Speed Response
H117
PM Starting Current
H118
PM Starting Time
H119
PM Stabilization Constant
H121
PM Minimum Frequency
H122
PM No-Load Current
H123
PM Starting Method Select
H131
PM Initial Magnet Position
Estimation 0 V Wait Times
H132
PM Initial Magnet Position
Estimation Detect Wait Times
H133
PM Initial Magnet Position
Estimation Detect Times
H134
PM Initial Magnet Position
Estimation Voltage Gain

4.6 Parameter group P

Function code
Function name
P001
Operation mode on expansion card 1 error
P003
[EA] terminal selection
P004
Pulse train input mode for feedback
P011
Encoder pulse-per-revolution (PPR) setting
P012
Simple positioning selection
P015
Creep speed
P026
Over-speed error detection level
P027
Speed deviation error detection level
P031
Accel/decel time input selection
P033
Torque command input selection
P034
Torque command setting
P036
Torque bias mode
P037
Torque bias value
P038
Torque bias polarity selection
P039 (32-bits)
Speed limit for torque-controlled operation (for-
ward rotation)
P040 (32-bits)
Speed limit for torque-controlled operation (reverse
rotation)
P041
Speed / torque control switching time
P044
Communication watchdog timer
P045
Inverter action on communication error
P046
DeviceNet default connection path
P048
Inverter action on communication idle mode
P049
Motor poles setting for RPM
P055
Pulse train frequency scale
P056
Time constant of pulse train frequency filter
MX2 Quick Start Guide
Monitoring and setting items
Set a level between 20% and 100% for the rated inverter
current
0.001 to 65.535 
0.01 to 655.35 mH
0.01 to 655.35 mH
0.0001 to 6.5535 Vpeak/(rad/s)
0.001 - 9999.000 kg/m²
0.001 to 65.535 
0.01 to 655.35 mH
0.01 to 655.35 mH
1 to 1000
20.00 to 100.00%
0.01 to 60.00 s
0 to 120%
0.0 to 25.5%
0.00 to 100.00%
00 (Normal ), 01 (IMPE)
0 to 255
0 to 255
0 to 255
0 to 255
Monitoring and setting items
00 (tripping), 01 (continuing operation)
00 (Speed reference, incl. PID)
01 (Encoder feedback)
02 (Extended terminal for EzSQ)
00 (Single-phase pulse [EA])
01 (2-phase pulse [90° difference] 1 ([EA] and [EB]))
02 (2-phase pulse [90° difference] 2 ([EA] and [EB]))
03 (Single-phase pulse [EA] and direction signal [EB])
32 to 1024
00 (simple positioning deactivated)
02 (simple positioning activated)
"start frequency" to 1000
0 to 1500
0 to 12000
00(digital operator), 03 (easy sequence)
00 (O terminal), 01 (OI terminal),
03 (digital operator), 06 (Option)
0 to 200
00 (disabling the mode),01 (digital operator),
-200 to +200
00 (as indicated by the sign), 01 (depending on the oper-
ation direction), 05(Option)
0 to 12000
0 to 12000
0 to 1000
0 to 9999
00 (tripping), 01 (tripping after decelerating and stop-
ping the motor), 02 (ignoring errors), 03 (stopping the
motor after free-running), 04 (decelerating and stop-
ping the motor)
0-7
00 (tripping), 01 (tripping after decelerating and stop-
ping the motor), 02 (ignoring errors), 03 (stopping the
motor after free-running), 04 (decelerating and stop-
ping the motor)
0 (0 pole), 1 (2 poles), 2 (4 poles), 3 (6 poles),
4 (8 poles), 5 (10 poles), 6 (12 poles), 7 (14 poles),
8 (16 poles), 9 (18 poles), 10 (20 poles), 11 (22 poles),
12 (24 poles),13 (26 poles),14 (28 poles), 15 (30 poles),
16 (32 poles),17 (34 poles), 18 (36 poles), 19 (38 poles)
10 to 320 (input frequency corresponding to the allow-
able maximum frequency)
1 to 200
Units
Run
Modbus
Default
mode
Register
edit
No.
0.01 [A]
1574h
0.001 []
1575h
0.01 mH
1576h
0.01 mH
1577h
0.0001
1578h
V/(rad/s)
0.001 kg/
1579h
0.001 []
157Bh
0.01 mH
157Ch
0.01 mH
157Dh
1581h
100
1582h
70.00
0.01 [s]
1583h
1.00
1584h
100
1586h
8.0
1587h
10.00
1588h
00
158Ah
10
158Bh
10
158Ch
30
158Dh
100
Units
Run
Modbus
Default
mode
Register
edit
No
1601h
00
1603h
00
1604h
00
1
160Bh
512
160Ch
00
0.01 [Hz]
160Fh
5.00
0.1 [%]
161Ah
115.0
0.01 [Hz]
161Bh
10.00
161Fh
00
1621h
00
1 [%]
1622h
1624h
00
1 [%]
1625h
1626h
00
0.01 [Hz]
1627h
0.00
1628h
0.01 [Hz]
1629h
0.00
162Ah
162Bh
0.01 sec.
162Eh
1.00
162Fh
00
1630h
1632h
00
1633h
0.1 [kHz]
1639h
1.5
0.01 sec.
163Ah
0.10
-
-
-
-
-
-
-
-
-
0
0
0
1
0
43