Centrifuge Decanter Control; Centrifuge Function - ABB ACS880 Supplement Manual

Centrifuge decanter control program (+n5150)
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

34 Signals and parameters
Parameters
No
Name/Value
74
74 Centrifuge
Decanter control
74.01
Centrifuge/
Decanter function
selection
Not selected
Decanter
Centrifuge
75
75 Centrifuge
function
75.01
Pattern reset
selection
Not selected
Reset now
DI1
DI2
DI3
DI4
DI5
DI6
Other
75.02
Manual halt
Not selected
Selected
DI1
DI2
DI3
DI4
DI5
DI6
Description
Selecting Centrifuge or Decanter control.
Selects Centrifuge or Decanter function.
Not selected.
Decanter function is selected for drive operation.
Note: Drive operates based on the setting in parameter
78.01 Decanter mode
select.
Centrifuge function is selected for drive operation. See
parameter group
75 Centrifuge
Settings for Centrifuge operation sequence
control.
Resets the centrifuge sequence.
Note: The drive must be stopped before reset is
possible.
Not selected.
Reset.
Reset through DI1.
Reset through DI2.
Reset through DI3.
Reset through DI4.
Reset through DI5.
Reset through DI6.
See
Terms and abbreviations
Shifts Centrifuge application to deceleration mode.
Not selected.
Selected
Halt through DI1.
Halt through DI2.
Halt through DI3.
Halt through DI4.
Halt through DI5.
Halt through DI6.
function.
on page
30
Def /FbEq16
Centrifuge
0
1
2
DI3
0
1
2
3
4
5
6
7
-
DI4
0
1
2
3
4
5
6
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents