Technical data

1.5
Technical data
Electrical data (hot-plug power supply unit)
Rated voltage range
Frequency
Rated current with basic configuration
Max. rated current
Effective power
Apparent power
Heat dissipation
Main power fuse in building installation 16 A
Protection class
20
100 V - 240 V
50 Hz - 60 Hz
100 V - 240 V / 4.4 A - 1.5 A
100 V - 240 V / 9.0 A - 5.0 A
max. 876 W
max. 884 VA
3154 kJ/h (2989 btu/h)
I