FRWM-IP-GATE
Operating Manual
IP-Gateway

Advertisement

Table of Contents
loading

Summary of Contents for Jung FRWM-IP-GATE

  • Page 1 FRWM-IP-GATE Operating Manual IP-Gateway...
  • Page 2: Table Of Contents

    4 Commissioning and setting up 5 Reset 6 Installation variants 7 Notifications 8 Troubleshooting 9 Maintenance 10 Decommissioning 11 Accessories, spare parts and service 48 12 Glossary 13 Technical data 14 Alarm and alert tones Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 3: Notes On The Operating Manual

    The operating manual only applies for the gateway. 1.2 Applicable documents The gateway is used in combination with the manufacturer’s smoke alarm devices with radio link (e.g., FRWM100WW). In addition to this operating manual, also Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 4 If you have questions about the product 1.3 CE conformity or require help with the installation, Albrecht Jung GmbH declares that the IP please contact our product support gateway is compliant with the fundamental department by telephone at requirements and other relevant provisions +49.23 55.8 06-0.
  • Page 5 Symbols from the current web app Edit (1) Numbered action steps Main menu f Symbol for an instruction or a required action 5 Result of an action 4 Problem associated with an action Symbol for a list • Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 6: Limited Warranty

    1.7 Warranty exclusion criteria Albrecht Jung GmbH directly, or through an Physical/mechanical damage authorized reseller, for a period of 2 years from the date of purchase. The limited war- If the device has been damaged, e.g., the...
  • Page 7 If the device has been exposed tempo- and therefore if the warranty claim is rarily or continuously to a temperature justified or unjustified. below 0°C or above 70°C, any warranty claim shall be forfeited. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 8: Limitation Of Liability

    Albrecht Jung GmbH shall be limited to the after-sales services shall be limited to the purchase price of the device.
  • Page 9: Safety Instructions

    Note the following when using the gateway: f Only use the device with the power unit and power cable provided. f Use the device only as intended and in a technically perfect condition. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 10 (e.g., failure of the Internet occurring smoke development connection). Any use that is not expressly • described as permitted in this operating manual Exceptions to the above require a writ- ten agreement with the manufacturer. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 11: Data Security

    Please observe chapter 9.3 of your smartphone, the gateway “Replacing the rechargeable or the smoke alarm device battery” on page 47. On request, Jung product support • will delete your data from its IT system Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 12 Nicotine and paint fumes • Paint finishes (e.g., wall paint) • Adhesives • Contamination of any kind • f Do not open the device. Exception: f See chapter 9.3 “Replacing the re- chargeable battery” on page 47. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 13 Sensitive components The device consists of sensitive components. f Do not throw the device. f Do not let the device fall. Do not exert any pressure on the device. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 14: Overview

    3 Web app The gateway is controlled using buttons 4 "Apartment" with gateway, with signal LEDs. You must be able to see smoke alarm device and router the light signal, even when the buttons are pressed. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 15 2 Radio button (A) with signal LED Switch-off after unplugging the • 3 Gateway button (B) with signal LED power cable on the device 4 Port for power unit Resetting the connection • 5 LAN port settings to the router Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 16: Commissioning And Setting Up

    Prior to commissioning, ensure the follow- the router via the LAN cable. It is strictly ing at the installation location: required for the installation. Internet connection • Router with LAN port • LAN or WI-FI connection • Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 17 5 “Gateway” is shown as the type and (2) Enter your email address and “JUNG” as the manufacturer. choose a password. (4) Enter the verification code on the The email address will be your name plate of your gateway. user name. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 18 LAN cable. Gateway starts: (5) Select LAN or WI-FI connection. For a more stable installation, we recommend the LAN connection. Gateway parameter query: f For a WI-FI connection, enter the WI-FI parameters and click “Save”. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 19 LAN cable and bring the gateway installation location. to the planned installation site. b) Ensure a minimum distance of 3 m to the other smoke alarm devices and the gateway. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 20 While the gateway is starting up the LEDs of the gateway button (B) and the radio button (A) become active in that order: Gateway starts: 5 Radio group is in learning mode for 10 minutes. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 21 5 You are now in the “Radio group” matically integrated into the radio menu. group, the radio button (A) on the gateway flashes intermittently indi- 5 Network scan complete. cating the already integrated radio group participants. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 22 Short acoustic signal from all All notifications are always sent to the user who created the apartment in the web app. installed smoke alarm devices The email address and mobile telephone number can be changed in the web app. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 23 (e.g. 0049). (2) Change the location of the gateway 5 All of the stored recipients will be if necessary. informed in case of an alarm. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 24 When it is switched off, no alarms will be forwarded, not even via GSM. When you reconnect the power cable, the gateway is placed in service again. You will receive an email stating "Gateway is again reachable". Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 25: Reset

    Press radio button (A) on the gate- (3) Press radio button with splint pin way until it flashes, then release. until it flashes, then release. Signal LED of radio button (A) 5 The device is in its default state. "Off" Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 26: Installation Variants

    Add further smoke alarm devices one after another to the radio group. To do this, press in the activation but- tons on the respective smoke alarm devices so that they are flush. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 27 5 The smoke alarm device has been successfully integrated into the radio group. 5 The changes get visible when you perform a network scan in the web app. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 28 A gateway that receives an alarm sends the alarm forwarding to other user alarm to the smoke alarm device in its radio accounts. group and triggers them. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 29 The web app creates 6 typical living areas react differently according to their settings. for each new apartment. For large dwell- ing units (e.g., kindergartens, dormitories) we recommend adding all rooms in the web app beforehand. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 30 To ensure that the radio group remains intact, DO NOT execute radio module reset. (1) Remove the power cable from the gateway. (2) Only execute the network reset (see chapter 5.1 “Gateway reset” on page 25). Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 31: Notifications

    Internet connection of the gateway 4 Gateway button (B) flashes as long is interrupted for more than 10 minutes. as battery operation continues. Possible causes are described in chapter 8.6 “The gateway is no longer connected to the server” on page 40. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 32 The initial installation was faulty, • this is particularly possible for installations without a gateway Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 33 11 months in the past, a reminder is sent curs in accordance with DIN 14676. to the person who created the dwelling unit. This message will be repeated month- ly until the executed maintenance has been documented in the web app. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 34: Troubleshooting

    Gateway of another manufacturer correctly connected Serial number belongs to a gateway Maintenance data will only • • from another manufacturer be read out if a network scan was executed beforehand Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 35 (4) For a WI-FI connection, ensure that WLAN-SSID, password and encryp- 4 A connection cannot be established. tion type are correct. 4 An error message appears in the web app. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 36 Smoke alarm device is installed • button (A) on the gateway until the too close or too far away from signal LED lights up and then goes off other smoke alarm devices again, and then release. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 37 A reset was not executed on the • alarm device in the same position smoke alarm device prior to activation changes to learning mode. 4 Radio LED on the smoke alarm (2) Replace defective smoke alarm device briefly lights up green. device. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 38 Remedy: (1) Reset the radio module on the gate- way (see chapter 5.1 “Gateway reset” on page 25, step 2). (2) Correct the position of the gateway. (3) Reconnect the gateway, with power. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 39 25, step 2). do not work, contact product support (3) Connect the USB cable to the gate- (see chapter 11.2 “Product support” way and restore the power supply on page 48). to the gateway. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 40 19 replacement Possible causes: device accordingly. (3) Dispose of old device Gateway is switched off (see chapter 10.1 “Disposal” on 4 Gateway is switched off. page 48). Signal LED gateway button (B) "Off" Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 41 Replace rechargeable battery if nec- router. essary (see chapter 9.3 “Replacing the (3) Restore power supply. rechargeable battery” on page 47). (4) Restart router. 5 Power supply to the gateway has been re-established. f Replace router if necessary. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 42 30 seconds (1) Check plug connection of the LAN cable. (2) Check LAN cable and replace if necessary. (3) Set up gateway connection again (see chapter 4.6 “Set up the gate- way” on page 18). Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 43 25). f Repeat network scan (see chapter 4.9 “Network scan” on (4) If the previously mentioned measures page 21). do not work, contact product support (see chapter 11.2 “Product support” on page 48). Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 44 (see chapter 4.9 “Network scan” on page 26). page 21). (1) Reset and set-up the radio group again with replacement device. (2) Repeat network scan (see chapter 4.9 “Network scan” on page 21). Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 45 (4) Set up radio group again (see chapter 4.8 “Setting up the radio group and integrating the gateway” on page 19). (5) After finishing the new installation, perform a network scan (see chapter 4.9 “Network scan” on page 21). Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 46: Maintenance

    (B) by mistake. The router is undamaged • and connected The radio button (A) on the • gateway is illuminated green The gateway button (B) on the • gateway is illuminated green and flashes every 10 seconds Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 47 (see chapter 11 “Accessories, spare (7) Put the battery compartment lid parts and service” on page 48). back on and screw it tight. 5 The rechargeable battery has been successfully replaced. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 48: Decommissioning

    FRWM100.. local waste disposal company. f Note that improper dispos- 11.2 Product support al can harm the environment. ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Telefon: +49.23 55.8 06-0 www.jung.de To reach our product suppor t please contact kundencenter@jung.de or use the...
  • Page 49: Glossary

    In this process, it queries the measured data of the connected smoke alarm device: Temperature • Contamination • Battery level • Signal level • The measured data are regularly and au- tomatically updated after the network scan. Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 50: Technical Data

    Colour White Material Dimensions (L x W x H) 10 x 10 x 3.6 cm Weight 210 g net 470 g gross weight (as delivered) Operation Browser, web app Update capability Via WI-FI and LAN Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 51 ISM-band, WI-FI, GSM Data encryption AES256 Maximum number of networked nodes 15 (including IP-Gateway) per group: Maximum number of networked radio groups with IP-Gateway Radio range 400 m (± 10 %) on open transmission field Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 52: Alarm And Alert Tones

    1 second continuous tone Moderately loud Power plug 60 seconds removed or 1 second, Power outage Start can take up to 2 minutes. Moderately loud Network reset No interval successful 1 second continuous tone Moderately loud Operating Manual: FRWM-IP-GATE - IP-Gateway...
  • Page 54 Impressum ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Telefon: +49.23 55.8 06-0 © ALBRECHT JUNG GMBH & CO. KG Telefax: +49.23 55.8 06-204 k_148817 Revision of the brochure 2017-01 kundencenter@jung.de www.jung.de...