Bryant 619PB Product Data
Hide thumbs Also See for 619PB:

Advertisement

619PB/538PR
High-Wall Ductless Split System
Sizes 09 to 30

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
A PERFECT BALANCE BETWEEN
BUDGET LIMITS, ENERGY SAVINGS AND
COMFORT.
The 619PB/538PR series ductless split systems are a matched
combination of an outdoor condensing unit and an indoor fan coil
unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This
selection of fan coils permits creative solutions to design problems
such as:
S
S
S
S
S
The ideal compliment to your ducted system when it is
impractical or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors. Advanced system
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
Add- ons to current space (an office or family room
addition)
Special space requirements
When changes in the load cannot be handled by the
existing system
When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork
Historical renovations or any application where
preserving the look of the original structure is essential.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 619PB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bryant 619PB

  • Page 1: Product Data

    A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT. The 619PB/538PR series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The fan coil is mounted on the wall, near the ceiling. This...
  • Page 2 These units are fast and easy to install ensuring minimal required, no energy is wasted moving air through ducts. disruption to customers in the home or workplace. This makes the 619PB/538PR ductless split systems the equipment of choice, EASY- TO- USE CONTROLS especially in retrofit situations.
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE INDOOR UNIT 619 = FAN COIL UNIT MA = ALL MODELS P = MODEL VOLTAGE A = 115/1/60 E = 208 - 230/1/60 MAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNIT SYSTEM TYPE B=1:1 Q = HEAT PUMP...
  • Page 4: Standard Features And Accessories

    STANDARD FEATURES AND ACCESSORIES INDOOR UNITS Ease Of Installation Mounting Brackets Low Voltage Controls Comfort Features Microprocessor Controls Wired Remote Control Wireless Remote Control Automatic Horizontal Air Sweep Air Direction Control Auto Restart Function Cold Blow Protection On Heat Pumps Freeze Protection Mode On Heat Pumps Turbo Mode Silence Mode...
  • Page 5: Dimensions - Indoor

    DIMENSIONS - INDOOR Fig. 2 – Indoor unit Unit Size W in (mm) D in (mm) H in (mm) Operating Weight lb (kg) 9K/12K 32.9 (835) 7.8 (198) 11.0 (280) 19.2 (8.7) 39.0 (990) 8.6 (218) 12.4 (315) 26.5 (12.0) 24K/30K 46.7 (1186) 10.2 (258)
  • Page 6: Clearances - Indoor

    CLEARANCES - INDOOR CEILING 6" (0.15m) min. 5" 5" (0.13m) (0.13m) min. min. (1.8m) FLOOR Fig. 4 – Indoor Unit Clearance CLEARANCES - OUTDOOR Air-inlet Air-outlet Fig. 5 – Clearances Outdoor Minimum Value UNIT in. (mm) 24 (609) 24 (609) 24 (609) 4 (101) 4 (101)
  • Page 7 SPECIFICATIONS - HEAT PUMP UNITS (MAQ SERIES) Size Outdoor Model 538PAQ009RBMA 538PAQ012RBMA 538PEQ009RBMA 538PEQ012RBMA 538PEQ018RBMA 538PEQ024RBMA 538PEQ030RBMA System Indoor Model 619PAQ009BBMA 619PAQ012BBMA 619PEQ009BBMA 619PEQ012BBMA 619PEQ018BBMA 619PEQ024BBMA 619PEQ030BBMA Energy Star Cooling Rated Capacity Btu/h 9,000 12,000 9,000 12,000 17,500 23,000 30,000 Cooling Cap.
  • Page 8: Cooling Performance Data

    COOLING PERFORMANCE DATA Cooling Outdoor conditions (DB) Model Indoor Conditions DB Indoor Conditions WB 77F(25C) 86F(30C) 95F(35C) 104F(40C) 113F(45C) 122F(50C) 7.43 7.83 9.74 8.38 6.11 5.11 69.8F(21C) 59F(15C) 6.68 6.69 8.18 7.37 4.36 3.74 Input 0.35 0.54 0.81 0.75 0.75 7.78 9.14 9.89...
  • Page 9: Heating Performance Data

    HEATING PERFORMANCE DATA Heating Outdoor conditions (DB) Model Indoor Conditions DB 53.6F(12C) 44.6F(7C) 39.2F(4C) 32F(0C) 24.8F(-4C) 19.4F(-7C) 17F(-8C) 5F(-15C) 11.2 11.1 10.89 10.65 9.87 9.11 8.27 6.71 59F(15C) Input 0.73 0.79 1.04 1.01 0.96 0.84 11.1 10.8 10.65 10.54 9.63 8.84 8.01 5.46...
  • Page 10: Mounting Template

    For those applications, contact your migration. Bryant representative. 3. Both lines must be insulated. Use a minimum of 1/2- in. MOUNTING TEMPLATE (12.7 mm) thick insulation. Closed- cell insulation is recommended in all long- line applications.
  • Page 11: Control System

    CAUTION WIRING Recommended Connection Method for Power and EQUIPMENT DAMAGE HAZARD Communication Wiring (To minimize communication wiring Failure to follow this caution may result in equipment interference) damage or improper operation. Power Wiring: S Be sure to comply with local codes while running wire The main power is supplied to the outdoor unit.
  • Page 12: Air Flow Data

    AIR FLOW DATA SYSTEM SIZE (115V) (115V) (208-230V) (208-230V) (208-230V) (208-230V) (208-230V) Turbo High Indoor (CFM) Medium Outdoor 1200 1200 1200 1200 1390 2130 2130 (CFM) AIR THROW DATA Unit Capacity Max Approximate Air Throw ft. (m) Approximate Air Throw ft. (m) range 9K, 12K 23 (7) 11 (3.5) - 23 (7)
  • Page 13: Fan And Motor Specifications

    FAN AND MOTOR SPECIFICATIONS System size (115V) (115V) (208-230V) (208-230V) (208-230V) (208-230V) (208-230V) material Indoor fan Type GL-98*655-N GL-98*655-N GL-98*655-N GL-98*655-N GL-107.5*760-IN GL-118*895-IN GL-118*895-IN Diameter inch Indoor fan Height inch 25.8 25.8 25.8 25.8 35.2 35.2 material Type ZL-421*117*8-3K ZL-421*117*8-3K ZL-421*117*8-3K ZL-421*117*8-3K ZL-460*180*10-3N ZL-560*139*12-3KN ZL-560*139*12-3KN...
  • Page 14: Wiring Diagrams

    WIRING DIAGRAMS EXPANSIVE VALVE 6(5) BLACK CN31 CN16 CN15 HEATER, CRANKCASE CN32 CN33 BLACK HEATER, CRANKCASE CN34 Dashed frame CN28 parts only for heat CN26 pump model. YELLOW BLUE(BLACK) L-IN YELLOW BLUE CN11 BROWN BLUE CN16 OPTIONAL L N S Wi-Fi INDOOR UNIT CN10(CN19)
  • Page 15 COMPRESSOR HEATER, CRANKCASE CN33 HEATER, CRANKCASE CN21 CN31 CN28 CN29 CN30 CN22 OPTIONAL: CN26 CN27 BLUE(BLACK) L-IN CN16 YELLOW YELLOW CN11 BLUE CN9-1 CN32-1 L1 L2 CN16 OPTIONAL WHITE WHITE L1L2 S DC-FAN Wi-Fi INDOOR UNIT Contoller 8(7) OUTDOOR UNIT REACTOR INDOOR WIRING DIAGRAM Power Input...
  • Page 16 OUT DOOR HEATER 1 CN414 CN15 L-OUT BLUE CN13 CN12 BLUE OUTDOOR CN14 MAIN BLACK YELLOW CN6-1 CN10 BLUE(BLACK) L-IN COMPRESSOR YELLOW CN11 CN16 OPTIONAL L1L2 S OUTDOORAMBIENT Wi-Fi INDOOR UNIT TEMPERATURE SENSOR Contoller 8(7) OUTDOOR UNIT INDOOR WIRING DIAGRAM OPTIONAL Wire Contoller Fig.
  • Page 17 L-OUT CN10 BLUE(BLACK) L-IN YELLOW CN11 YELLOW CN16 OPTIONAL L1L2 S Wi-Fi INDOOR UNIT Contoller 8(7) OUTDOOR UNIT INDOOR WIRING DIAGRAM OPTIONAL Wire Contoller Fig. 12 – Wiring Diagram Size 24 (208- 230V) INDOOR UNIT CONTROL BOARD INPUT or OUTPUT VALUE Power Voltage :AC 230V L_IN Power Voltage :AC230V...
  • Page 18 BLACK COMP BLUE Applicable to the units adopting DC motor only BLUE(BLACK) CN12 CN11 CN33 L-IN YELLOW CN11 BLACK CN16 OPTIONAL L1L2 S YELLOW Wi-Fi INDOOR UNIT DRIVER BOARD Contoller BLUE BLACK 8(7) HEAT1 OUTDOOR UNIT CN10 INDOOR WIRING DIAGRAM CN54 OPTIONAL The electric heating...
  • Page 19: Guide Specifications

    GUIDE SPECIFICATIONS INDOOR WALL- MOUNTED DUCTLESS UNITS Size Range: 3/4 to 2 1/2 Ton Nominal Cooling and Heating Capacity Model Number: 619P PART 1 - GENERAL The unit shall have the following functions as a minimum: 1. An automatic restart after power failure at the same 1.01 System Description operating conditions as at failure.
  • Page 20 Catalog No: PDS538- 619P- 02 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Edition Date: 05/15 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

This manual is also suitable for:

538pr

Table of Contents