Appendix A (Alternate Floor Protection) - Jøtul F 600 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Part list for Jøtul F 600
Pos.
no. Description
2
Tube Frame Holder
3
Handle
4
Ash House Compl.
5
Ash Door
6
Smoke Outlet
7
Fire Grate
8
Leg
9
Decorative Cover Side
1 0
Door Right w/o Glass, Ver 3
1 1
Door Left w/o Glass, Ver 3
1 2
Bottom
1 3
Inner Bottom, Front Part
1 4
Inner Bottom, Rear Part
1 5
Rear Plate
1 7
Air Manifold
1 8
Front
1 9
Inner Front
2 0
Side Right
2 1
Side Left
2 2
Ash Lip Front
2 3
Top
2 4
Tube Holder Upper Right
2 5
Tube Holder Upper Left
2 6
Tube Holder Bottom Right
2 7
Tube Holder Bottom Left
2 8
Inspection Cover
2 9
Side Door
3 0
Burnplate Side Door
3 1
Burnplate Left
3 2
Burnplate Rear
3 3
Ash Lip Side
3 4
Air Valve
3 5
Baffle Plate
3 6
Top Cover
3 7
Nut Stainless
3 8
Screw Hexagon Stainless
3 9
Screw Hexagon
4 0
Screw Collar Hexagon
4 1
Screw Collar Hexagon
4 2
Screw Selfthread
4 3
Screw Collar Hexagon
4 4
Screw Collar Hexagon
4 5
Nut Hexagon
4 6
Screw Panh. (Front Door)
4 7
Washer
4 8
Latch Bolt Ash Door
4 9
Screw Allen
5 0
Screw Hexagon Stainless
5 1
Screw Collar Hexagon
5 2
Screw Collar Hexagon
5 3
Screw Collar Hexagon
5 4
Nut Collar Hexagon
5 5
Washer
5 6
Wooden Knob Ash Door
5 7
Spring for Latch Bolt
5 8
Hinge Pin Front/Side Door
5 9
Screw Syl. Head
6 0
Gasket (Door to Front)
6 1
Latch
6 2
Latch Bolt
63
Glass Clip
6 4
Ash Pan
6 5
Handle for Air Vent
6 8
Hinge Pin, Ash Door
6 9
Gasket (Ash Door)
7 0
Gasket (Glass)
7 1
Gasket (Top)
7 2
Gasket (Ash House)
7 3
Gasket (Left Door Middle)
7 4
Sleeve for Door Hinge
7 5
Gasket (Side Door)
7 6
Gasket (Smoke Outlet)
7 7
Tube First From Front
7 8
Tube Second From Front
7 9
Tube Third From Front
8 0
Tube Forth From Front
8 2
Bottom Heatshield
8 3
Heatshield Top Exit
8 4
Rear Heatshield
Pos.
no. Description
8 5
Air Restrictor
8 6
Insulation Blanket
8 7
Glass
8 8
Front Door Hinge
8 9
Gasket (Top Cover)
9 0
Shaft Collar Ø6 X Ø12 X 6 mm
9 1
Latch Bolt Side Door
9 2
Washer
9 3
Latch
9 4
Washer
9 5
Washer, Insulating
9 6
Wooden Knob Side Door
9 7
Distance Sleeve for Side Door
9 8
Screw Pan Head
9 9
Pin
100 Air Chamber Complete
101 Handle Side Door Complete
102 Adapter Outside Air
Alternate floor protection
All floor protection materials must be non-combustible ie.
metal, brick, stone, mineral fiber boards). Any combustible
material may not be used.
The easiest means of determining if a proposed alternate floor
material meets requirements listed in this manual is to follow
this procedure.
R-value = thermal resistance
k-value = thermal conductivity
C-value = thermal conductance
1. Convert the specification to R-value;
a. If R-value is given, no conversion is needed.
b. If k-value is given with a required thickness (T) in inches:
R=1/k X T.
c. If C-value is given: R=1/C.
2. Determine the R-value of the proposed alternate floor
protector.
a. Use the formula in Step 1 to convert values not
expressed as "R".
b. For multiple layers, add R-values of each layer to
determine overall R-value.
3. If the overall R-value of the system is greater than the R-
value of the specified floor protector, the alternate is
acceptable.
Example:
The specified floor protector should be 3/4" thick material with
a k-factor of 0.84. The proposed alternate is 4" brick with a C-
factor of 1.25 over 1/8" mineral board with a k-factor of 0.29.
Step A. Use formula above to convert specifications
to R-value. R=1/k X T= 1/.84 X .75 = .893
Step B. Calculate R of proposed system.
4" brick of C-1.25, therefore
R brick = 1/C = 1/1.25 = 0.80.
1/8" mineral board of k = 0.29 therefore
R mineral board = 1/.29 X 0.125 = 0.431
Total R = R brick + R mineral board=
0.8 + 0.431=1.231
Step C. Compare proposed system R = 1.231 to specified R of
0.893. Since R is greater than required, the system is acceptable.
Definitions:
Thermal conductance =
C =
Btu
=
(hr)(ft
2
)(F)
Thermal conductivity =
k =
Btu
=
2
(hr)(ft
)(F)
(m
Thermal resistance =
R =
Btu
=
2
(hr)(ft
)(F)
For the Jøtul F 600 woodstove requires floor protection with
a minimum insulating r value of 0.5.
Alcoves require an r value of 1.6.
USA/CANADA
W
(m
2
)(K)
W
=
(Btu)
2
)(K)
(hr)(ft)(F)
2
(m
)(K)
=
(Btu)(inch)
2
W
(hr)(ft
)(F)
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents