Installation and operating manual
(PVI-3.8/4.6-I-OUTD Rev.: 1.5)
5.5.6.13

MPPT

This function is used in order to set the parameters for the Maximum Power Point
Tracker function.
MPPT Amplitude: this setting allows you to choose the amplitude of disturbance
introduced in DC in order to establish the optimal work point. There are 3 choices
(LOW, MEDIUM, HIGH). The default setting is MEDIUM.
You can enable or disable the scan function to identify the maximum multiples.
The time interval for system maximum multiples scans can be set using this function.
The default setting is 15 minutes.
You may also decide to perform a manually scan, by using the specific control
5.5.6.14

Alarm Message

Follow the procedure described below in order to program the error message that will
be shown on the display:
Pressing the ENTER key will allow you to access the relevant submenu
MPPT Amplitude
Multi-Max Scan
MPPT scan En/Dis
Scan Interval
Manual Scan
Alarm Message
MPPT Amplitude
Low
Enable
15 min
Page 75 of 95