Advertisement

INTRODUCTION
Thank you for choosing this De'Longhi product. Please take a few
minutes to read these instructions. This will prevent running any
risks or damaging the appliance.

Symbols used in these instructions

Important warnings are identified using the symbols listed
below. It is absolutely necessary to pay close attention to these
warnings.
Failure to follow the indications given could lead to electrical
shocks, serious injury, burns, fire or damage to the appliance.
Danger!
Failure to comply could lead to injury from electrical shock and
risk of death.
Attention!
Failure to comply could lead to injury or damage to the appli-
ance.
Please note:
This symbol highlights advice and important information for the
user.

Problems and repairs

For any repairs, always consult the Technical Service Centres
authorised by the manufacturing company. Always request
original replacement parts. Repairs performed by unqualified
personnel can be dangerous and void the warranty.
WARNINGS

Essential safety requirements

Only use the room air conditioner according to the instructions
in this manual. These instructions do not cover every possible
condition and situation that could occur. Common sense and
prudence must always be followed during installation, opera-
tion and storage of any electrical appliance. This appliance was
built for household use and must not be used for other purposes.
Attention!
This appliance can be used by children
aged from 8 years and above and per-
sons with reduced physical, sensory or
mental capabilities or lack of experience
and knowledge if they have been given
supervision or instruction concerning
use of the appliance in a safe way and
understand the hazards involved. Chil-
dren shall not play with the appliance.
Cleaning and user maintenance shall not
be made by children without supervi-
sion.
Do not set heavy or hot objects on the appliance.
Danger! Since the appliance uses electricity, the follow-
ing safety instructions must be followed:
Modifying or changing the characteristics of the appliance
in any way is dangerous.
The appliance must be installed according to national laws
governing electrical systems.
For any repairs, always consult the Technical Service Cen-
tres authorised by the manufacturing company. Repairs
performed by incompetent individuals can be hazardous.
This appliance must be earthed. Have the electrical system
checked by a qualified electrician.
Avoid using extension cords.
Before any cleaning or maintenance operation, always un-
plug from the mains.
Do not pull on the electrical cord to move the appliance.
Do not install the appliance in areas where the air may con-
tain gas, oil or sulphur or near heat sources.
If the power cable is damaged, it must
be replaced by the manufacturer or the
manufacturer's Customer Services in or-
der to avoid all risk.
Please note:
Clean the air filter at least once a week.
When transporting, the appliance must be kept upright or
resting on one side. Before transporting, drain all the water
from the appliance. After transporting, wait at least one
hour before turning on the appliance.
Do not cover the appliance with plastic bags when stored.
The packaging materials are recyclable. Please place them
in the appropriate recycling collection containers.
At the end of its life, deliver the air conditioner to the ap-
propriate collection centres.
15

Advertisement

Table of Contents
loading

Summary of Contents for DeLonghi Pinguino PAC AN112 SILENT

  • Page 1 and knowledge if they have been given INTRODUCTION Thank you for choosing this De'Longhi product. Please take a few supervision or instruction concerning minutes to read these instructions. This will prevent running any use of the appliance in a safe way and risks or damaging the appliance.
  • Page 2 WARRANTY AND TECHNICAL ASSISTANCE Check the plate for the type of refrigerant gas used Warranty and technical assistance conditions are indicated in the in your appliance. documentation provided with your appliance. Specific information regarding appliances with TECHNICAL DATA R410A refrigerant gas Power supply See characteristic plate R410 is a refrigerant gas that complies with EC ecology regula-...
  • Page 3 A9 Power supply cable • Open the window. A10 Drainage hose with 2 caps • Put the crosspiece B7 in the window, extending it the en- A11 Remote control signal receiver tire width of the window (fig. 3). • Once the crosspiece has been extended, it can be attached Description of accessories (See page 3 - B) by screwing in the remaining two screws provided.
  • Page 4 • Open the window or French door slightly and set the outlet B9 in place as shown in figure 7. in the window in the wood in the wall: we glass base of the r e c o m m e n d French door insulating section of the wall...
  • Page 5 NOTE: for semi-permanent installations, we recommend leav- ing a door slightly open (even just 1 cm) to ensure the proper air exchange. CONTROL PANEL C11 C12 C13 C14 CONTROL PANEL DESCRIPTIONS (C) C16 SILENT symbol C1 ON/STAND-BY (on/off) key C17 Set temperature values, programmed on/off time C2 Function selection key MODE (air conditioner, dehumidifier, C18 Fan speed indicator C19 Timer indicator...
  • Page 6 CONTROL PANEL OPERATION HIGH TURNING THE APPLIANCE ON AND OFF Operating curve MEDIUM Insert the plug in the socket. Two dashes appear on the display indicating that the appliance is in stand-by and the keys light up. Touch the (C1) key to turn on the appliance. TEMPERATURE When the appliance comes on, the last function set before it was shut off is activated.
  • Page 7 The speeds available are: To correctly set this mode: Touch the MODE key until the fan Minimum speed: when maximum silent operation is • symbol appears. • Select the desired fan speed by touching the key. desired. The speeds available are: Medium speed: when the noise level needs to be low Minimum speed: when maximum silent operation is but with a good comfort level.
  • Page 8 • Use the + (C4) or - (C5) key to set the number of hours INSERTING OR REPLACING BATTERIES until the appliance should shut down. • Remove the cover on the back of the remote A few seconds after the timer is set, the setting is acquired, the •...
  • Page 9 SELF-DIAGNOSIS The appliance has a self-diagnosis system that identifies some operating errors. The error messages appear on the appliance display. IF THE FOLLOWING APPEARS ON IF THE FOLLOWING APPEARS ON IF THE FOLLOWING APPEARS ON THE DISPLAY... THE DISPLAY... THE DISPLAY... “Low Temperature”...
  • Page 10 CLEANING Before every cleaning or maintenance operation, shut down the appliance using the key. Then pull the plug. CLEANING THE APPLIANCE We suggest cleaning the appliance with a damp cloth and then drying it.For safety reasons, do not wash the air conditioner with water.
  • Page 11 TROUBLESHOOTING Check the following points before calling the authorised Technical Service Centre in your area. PROBLEMS CAUSES SOLUTIONS The air conditioner does not turn on it is not plugged in plug it in there is no power wait the internal protection device was call the help centre triggered The air conditioner works for a short...

Table of Contents