Bomag BW 177 D-4 Operating Instructions Manual page 48

Single drum roller
Table of Contents

Advertisement

Operation
Fig. 48
Switch the rotary switch for vibration amplitude
l
pre-selection (Fig. 48) to position "0".
Fig. 49
Check, whether the emergency stop switch
l
(Fig. 49) is unlocked.
Fig. 50
Turn the ignition key (Fig. 50) to position "I".
l
48
Fig. 51
All control and warning lights (Fig. 51) in the instru-
ment cluster light up for a moment.
The engine oil pressure warning light (d) flashes,
the charge control light (f) and the parking brake
warning light (k) stay on.
Under cold ambient temperatures the preheating
control lamp (b) will also light up. Do not start be-
fore the preheating control lamp (b) has gone out.
Caution
!
Run the starting process for maximum 20 sec-
onds without interruption and pause for a
minute between starting attempts.
If the engine has not started after two attempts
perform trouble shooting.
i
Note
The starter switch is designed with a re-start lock.
For a new starting attempt the ignition key must
first be turned back to position "0".
BOMAG
BW 177 D-4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents