19.2 Heat Mode Performance Data

Unit setting: Standard piping length, Hi Fan, Heat mode at 30°C
Voltage: 230V
19.2.1
CS-CZ9SKE/CU-CZ9SKE
Indoor (°C)
-20
DB
TC
24
1921
20
1995
16
2049
Indoor (°C)
Outdoor WB (°C)
12
DB
TC
24
4267
20
4688
16
4987
19.2.2
CS-CZ12SKE/CU-CZ12SKE
Indoor (°C)
-20
DB
TC
24
2745
20
2850
16
2927
Indoor (°C)
Outdoor WB (°C)
12
DB
TC
24
5498
20
6040
16
6425
TC
- Total Cooling Capacity (W)
SHC - Sensible Heat Capacity (W)
IP
- Input Power (W)
-15
IP
TC
IP
1209
2549
1377
1122
2646
1275
1043
2723
1185
IP
1412
1411
1413
-15
IP
TC
IP
1758
3398
1884
1632
3528
1744
1518
3631
1622
IP
1948
1947
1949
Outdoor WB (°C)
-7
TC
IP
TC
2959
1323
3294
3135
1274
3393
2973
1125
3505
Outdoor WB (°C)
-7
TC
IP
TC
3631
1883
4246
3848
1813
4374
3649
1600
4518
109
2
7
IP
TC
1245
4120
1216
4420
1192
4656
2
7
IP
TC
1721
5309
1682
5695
1648
5999
IP
1418
1421
1420
IP
1956
1960
1958