I
_ _ _ TRAIL SP1 scrolls across the display and toggles with the tracking setting
for the selected setpoint. Using the
then press
A setpoint with TRAIL SP1 enabled will track the setpoint value of SP 1, with the setpoint value
of the tracking setpoint becoming an off set value.
J
_ _ _ SHOW SP ON BAR scrolls across the display and toggles with the cur-
rent setting. If you enable this feature, then the selected setpoint's value will be
marked on the graph by a single bar. Multiple setpoints may have this option
enabled. Use the
K
_ _ _ EDIT SETPOINT scrolls across the display and toggles with SKIP. You are
now back at 7.2A. To edit another setpoint, follow the instructions from 7.2A–K
again. If you do not wish to edit another setpoint, press
7.3 - Edit SP PIN number
A
_ _ _ EDIT SP PIN NUMBER scrolls across the display and toggles with SKIP.
Press
to skip and return to the operational display, or the
then
to ENTER and change your PIN number.
B
_ _ _ ENTER NEW SP PIN NUMBER scrolls across the display and toggles with
the current PIN (default 1). Using the
number. Then press
Copyright © 2015 Defi ne Instruments
.
and
buttons to select NO or YES, and then press
to exit to the operational display.
and
buttons, select OFF or ON, and
and
buttons, enter your new SP PIN
TEX-BAR-MAN-15V05 (0903)
21
.
now to skip to 7.3.
button and
Need help?