GENERAL INSTRUCTIONS

THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to
conform with local codes. Installation practices vary from region to region and it is important to know the
specifi cs that apply to your area, for example in Massachusetts State:
This product must be installed by a licensed plumber or gas fi tter when installed within the
commonwealth of Massachusetts.
The appliance damper must be removed or welded in the open position prior to installation of an
appliance insert or gas log.
The appliance off valve must be a "T" handle gas cock.
The fl exible connector must not be longer than 36 inches (0.9m).
A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.
The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent
sealed combustion product.
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or ANSI
Z223.1 and NFPA 54 in the United States.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psig (35 mb). The appliance
must be isolated from the gas supply piping system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (35
mb). When installed with a blower or fan, the junction box must be electrically connected and grounded in
accordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian Electrical
Code in Canada or the ANSI / NFPA 70 National Electric Code in the United States. In the case where
the blower is equipped with a power cord it must be connected into a properly grounded receptacle. The
grounding prong must not be removed from the cord plug.
The following does not apply to inserts; as long as the required clearance to combustibles is maintained,
the most desirable and benefi cial location for an appliance is in the center of a building, thereby allowing the
most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the room where
the appliance is to be located should be considered. If possible, you should choose a location where the
vent will pass through the house without cutting a fl oor or roof joist. If the appliance is installed directly on
carpeting, vinyl tile or other combustible material other than wood fl ooring, the appliance shall be installed
on a metal or wood panel extending the full width and depth, unless otherwise tested.
17 1/2"
445mm
25 5/8"
651mm
23 5/8"
600mm
12 3/4"
324mm
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certi ed in the U.S.
by the National Fireplace
Institute ® (NFI) as NFI Gas
Specialists
www.n certi ed.org
4.1
5
Ø 4"
102mm
Ø 7"
EN
178mm
23 1/2"
597mm
W415-2207 / A / 08.28.17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gds25p-1

Table of Contents