MINIMUM MANTEL OR SHELF CLEARANCES

4.10
MINIMUM MANTEL OR SHELF CLEARANCES
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, HEARTH, MANTEL, FRONT,
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, HEARTH, MANTEL, FRONT,
When the appliance is rear vented, a mantel or shelf may be installed above the GDS25 at a minimum
When the appliance is rear vented, a mantel or shelf may be installed above the GDS25 at a minimum
distance of 8" (203mm).
distance of 8" (203mm).
COMBUSTIBLE
MANTEL OR
TRIM MATERIAL
ETC.) ARE CLEARLY MAINTAINED.
ETC.) ARE CLEARLY MAINTAINED.
MAX. MANTEL DEPTH
8" (203mm)
MIN.
WARNING
!
WARNING
!
COMBUSTIBLE
NON-COMBUSTIBLE
12" (305mm)
2" (51mm)
2"
(51mm)
BRICK
0" (0mm) IF NON-
COMBUSTIBLE
FINISHING IS
USED SUCH AS
BRICK AND STONE
1" (25mm)
24.5"
(622mm)