Napoleon Arlington GDS20N Installation And Operation Instructions Manual

Napoleon Arlington GDS20N Installation And Operation Instructions Manual

Natural gas/propane

Advertisement

Quick Links

1
W415-0496 / B / 08.10.05
W415-0496 / B / 08.10.05

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon Arlington GDS20N

  • Page 1 W415-0496 / B / 08.10.05 W415-0496 / B / 08.10.05...
  • Page 2: Warnings And Safety Precautions

    WARNINGS & SAFETY PRECAUTIONS WHAT TO DO IF YOU SMELL GAS W415-0496 / B / 08.10.05...
  • Page 3 TABLE of CONTENTS 18. Finishing Warnings and Safety Precautions Glass door install and removal What to do if you smell gas Cast Front Installation and removal Warranty 19. Logo Placement General Instructions Log Placement General Information 20. Operation / Maintenance Care of Glass and Plated Parts 21.
  • Page 4: Warranty

    NAPOLEON products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. The complete fireplace is test-fired and thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY...
  • Page 5: General Instructions

    Expansion / contraction noises during heating up and cool- GENERAL INSTRUCTIONS ing down cycles are normal and to be expected. THIS GAS STOVE SHOULD BE INSTALLED AND SERVICED This appliance is only for use with the type of gas indicated BY A QUALIFIED INSTALLER to conform with local codes.
  • Page 6: Location And Clearances

    LOCATION & CLEARANCES 2" Provide adequate accessibility clearance for servicing AT A DISTANCE OF FROM THE WALL INSTALLATION OR SERV 5" ICE TO THE BLOWER MAY NOT BE PRACTICAL A MINIMUM OF and operating the stove. WILL BE REQUIRED IN ORDER TO INSTALL THE BLOWER Never obstruct the front opening of the stove.
  • Page 7: Blower Installation

    BLOWER INSTALLATION Blower ( SEE LOCATION AND CLEARANCES 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower. 3. Connect the black blower wire to the black wire coming from below the unit.
  • Page 8: Terminal Installation

    AIR TERMINAL INSTALLATIONS FIGURE 8 INSTALLATIONS CANADIAN U.S.A. 12 INCHES 12 INCHES Clearance above grade, veranda porch, deck or balcony. Clearance to windows or doors that open. 12 INCHES 9 INCHES Clearance to permanently closed windows. 12 INCHES* 12 INCHES* Vertical clearance to ventilated soffit located above the terminal within 18 INCHES** 18 INCHES**...
  • Page 9: Venting

    VENTING • For optimum flame appearance and stove performance, VENTING LENGTHS & keep the vent length and number of elbows to a mini AIR TERMINAL LOCATIONS mum. Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct • The air terminal must remain unobstructed at all times. Temp or American Metal Amerivent venting components.
  • Page 10: Typical Vent Installations

    TYPICAL VENT INSTALLATIONS NOTE: When terminating vertically above 15', the restrictor plate must be in the fully closed position. Refer to Restricting Vertical Vents. FIGURES 3 a-c SPECIAL VENT INSTALLATIONS PERISCOPE TERMINATION Use the GD201 periscope kit to locate the air termination above grade.
  • Page 11: Elbow Vent Length Values

    DEFINITIONS ELBOW VENT LENGTH VALUES for the following symbols used in the venting calcula- feet inches tions and examples are: 1° 0.03 > - greater than 15° 0.45 > - equal to or greater than 30° 11.0 < - less than 45°* 1.35 16.0...
  • Page 12 HORIZONTAL TERMINATION when (H ) > (V Example 2: 90° Simple venting configuration (only one 45º and 90° elbow) 90° FIGURE 8 See graph to determine the re- 45° quired vertical rise V for the re- FIGURE 7 quired horizontal run H 90°...
  • Page 13: Vertical Termination

    VERTICAL TERMINATION when (H ) < (V Example 3: FIGURE 9 FIGURE10 90° 90° 45° 45° 90° See graph to determine the required vertical rise V the required horizontal run H = 5 ft = 10 ft = 5 + 10 = 15 ft = 3 ft = 2.5 ft = 3 + 2.5 = 5.5 ft...
  • Page 14 VERTICAL TERMINATION when (H ) > (V Example 4: Simple venting configurations = 1 ft = 1.5 ft = 1 + 1.5 = 2.5 ft FIGURE 11 = 6 ft = 2 ft = 6 + 2 = 8 ft = .03(one 45º...
  • Page 15: Wall And Ceiling Protection

    WALL AND CEILING PROTECTION VERTICAL INSTALLATION FIGURE 16 This application occurs when venting through a roof. FIGURE 17 Installation kits for vari- ous roof pitches are available from your Na- poleon dealer. See Ac- cessories to order the specific kit required. 1.
  • Page 16: Vertical Venting Installation

    4. If more than one length of liner needs to be used to HORIZONTAL VENTING INSTALLATION reach the stove, couple them together as illustrated in FIGURE 24. Seal the joints using the same procedure as FOR SAFE AND PROPER OPERATION OF THE described above.
  • Page 17: Stove Vent Connection

    7. In the attic, slide the vent pipe collar down to cover up the open end of the shield and tighten. This will prevent any materials, such as insulation, from filling up the 2" air space around the pipe. STOVE VENT CONNECTION 1.
  • Page 18: Glass Door Installation And Removal

    FINISHING CAST FRONT INSTALLATION GLASS DOOR INSTALLATION AND REMOVAL AND REMOVAL Note: It is not necessary to remove the cast front, in 1. Lift the top cast piece off of the unit. order to remove the door. 2. Detach the front cast piece from the side pieces by removing the screws from the brackets located in the upper 1.
  • Page 19: Logo Placement

    LOGO PLACEMENT Remove the backing from the the logo and position onto the control door as shown. LOG PLACEMENT It is not necessary to remove the cast front, however, this will make for a more simple log installation. In order to assemble the log set, the door must be removed, see Cast Front / Glass Door Removal in the FINISHING section of this manual.
  • Page 20 OPERATION / MAINTENANCE Allow several minutes (5-15) for the flame Purge all gas lines with the glass door removed. Assure that a continuous gas flow is at the burner before closing to stabilize after ignition. the door. OPERATING INSTRUCTIONS The on-off switch is located on the back of the unit at the Simply open a window to sufficiently ventilate the room.
  • Page 21: Maintenance

    MAINTENANCE 2. Keep the control compartment, logs, burner, air shut- TURN OFF THE GAS AND UNPLUG ter opening and the area surrounding the logs clean by ELECTRICAL POWER BEFORE SERVICING vacuuming or brushing, at least once a year. THE STOVE! 3.
  • Page 22: Replacement Parts

    REPLACEMENTS Contact your dealer for questions concerning prices and 1. M & S ODEL ERIAL UMBER OF FIREPLACE availability of replacement parts. Normally all parts can 2. I NSTALLATION DATE OF FIREPLACE be ordered through your Napoleon dealer or distributor. 3.
  • Page 23 W415-0496 / B / 08.10.05 * WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
  • Page 24: Troubleshooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED SYMPTOM PROBLEM TEST SOLUTION No spark at pilot burner Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor.
  • Page 25 SYMPTOM PROBLEM TEST SOLUTION Main burner goes out; REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON" pilot goes out. Vent re-circulating - check joint seals and installation. - loosen and tighten thermocouple Thermocouple shorting or - clean thermocouple and valve connection. faulty.
  • Page 26 W415-0496 / B / 08.10.05...
  • Page 27 W415-0496 / B / 08.10.05...
  • Page 28 W415-0496 / B / 08.10.05...

This manual is also suitable for:

Arlington gds20p

Table of Contents