Instructions for Operation with SINAUT ST1
3.2.2

Configuration Required for TIM11 and TIM011B

If the MD2 modem is connected to the TIM11 or TIM011B, it is necessary to enter
the parameters for the TIM module listed below in the SINAUT ST1 startup
program.
Table 3-7
Operating
Mode
of the MD2
1200 bps
2400 bps
1) Both half-duplex (DUPL = 0) and full-duplex operating mode (DUPL = 1) can be set.
3.2.3

Avoiding Problems When Exchanging Modems

Note the following points when using the MD2 to replace a defective SINAUT ST1
dedicated line modem:
Set the dedicated line properties, operating mode and the character
recognition on both DIL switches before beginning operation.
Use the cable supplied with the MD2 for connecting the MD2 to the LTOP.
If the MD2 is used in a network together with an MD124 at baud rate 2400 bps
and the MD124 is hardware version ≤ 3, the MD124 has to be set to baud rate
2400VF.
6NH7811-0AA22
3-6
Configuration Required for TIM11 and TIM011B
Baud rate on the
MD2
OFF
ON
1 2 3
4
5
OFF
ON
1 2 3
4
5
Basic Parameters for TIM11 or TIM011B
MTYP
BAUD
DUPL
1
1
1200
1
1
2400
© Siemens AG 2002 All Rights Reserved
SINT
SZEI
)
0
0
)
0
0
MD2 Modem (07/2002)