9. Multiple outdoor units control
9.6 Dip switch functions
<Outdoor unit>
• Set refrigerant address on each outdoor unit from 1 to 6.
Note: Do NOT use refrigerant address 0 as 0 is used for FTC (Master). The address range is from 1 to 6.
Split model (SW1-3 to SW1-6)
Refrigerant address number
Dip switch
Add. 1
Add. 2
SW1-1
SW1-2
SW1-3
ON
OFF
SW1-4
OFF
ON
SW1-5
OFF
OFF
SW1-6
OFF
OFF
<FTC: Master>
• Set Dip SW4-1 and SW4-2 to ON.
• For more details refer to "5. Dip Switch setting."
<FTC: Slave>
• Set Dip SW4-1 to ON "Active :multiple outdoor unit control".
• Set Dip SW1-7 (Outdoor unit type) on each slave unit according to each connected outdoor unit type.
• Set only Dip-SW1-3 to ON on the slave unit that runs DHW operation.
Dip switch
Function
SW1 SW1-1 Bolier
Heat pump maximum outlet water
SW1-2
temperature
SW1-3 DHW tank
SW1-4 Immersion heater
SW1-5 Booster heater
SW1-6 Booster heater function
SW1-7 Outdoor unit type
SW1-8 Wireless remote controller
SW2 SW2-1 Room thermostat1 input (IN1) logic change Zone1 operation stop at short
SW2-2 Flow switch1 input (IN2) logic change
SW2-3 Booster heater capacity restriction
SW2-4 Cooling mode function
"Automatic switch to backup heater only
SW2-5
operation (When outdoor unit stops by error)"
SW2-6 Mixing tank
SW2-7 2-zone temperature control
SW2-8 Flow sensor
SW3 SW3-1 Room thermostat2 input (IN6) logic change Zone2 operation stop at short
SW3-2 Flow switch2 input (IN3) logic change
SW3-3 Flow switch3 input (IN7) logic change
SW3-4
SW3-5 Heating mode function
SW3-6 2-zone valve ON/OFF control
SW3-7
SW3-8
SW4 SW4-1 Multiple unit control
SW4-2 Position of multiple outdoor units control Slave
SW4-3
SW4-4
SW4-5 Emergency mode (Heater only operation) Normal
SW4-6 Emergency mode (Bolier operation)
SW5 SW5-1
SW5-2 Advanced auto adaptation
SW5-3
SW5-4
SW5-5
SW5-6
SW5-7
SW5-8
*1 When FTC (Master) in Hydrobox is set as Slave.
*2 Set Dip SW2-6 to ON in "System 3 (2 zone)" and in "System 4 (with Boiler)" mentioned in "9.2 Pipe work."
Add. 3
Add. 4
Add. 5
Add. 6
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
WITHOUT Bolier
55˚C
WITHOUT DHW tank
WITHOUT Immersion heater
WITHOUT Booster heater
For heating only
Split type
WITHOUT Wireless remote controller WITH Wireless remote controller
Failure detection at short
Inactive
Inactive
Inactive
WITHOUT Mixing tank
Inactive
WITHOUT Flow sensor
Failure detection at short
Failure detection at short
Inactive
Inactive
Inactive
Normal
Inactive
Packaged model (SW7-3 to SW7-6)
Dip switch
Add. 1
SW7-1
SW7-2
OFF
SW7-3
ON
ON
SW7-4
OFF
ON
SW7-5
OFF
OFF
SW7-6
OFF
ON
WITH Bolier
60˚C
WITH DHW tank
WITH Immersion heater
WITH Booster heater
For heating and DHW
Packaged type
Zone1 operation stop at open
Failure detection at open
Active
Active
Active
WITH Mixing tank
Active
WITH Flow sensor
Zone2 operation stop at open
Abnormality detection at open
Abnormality detection at open
Active
Active
Active
Master
"Emergency mode (Heater only operation)
(To be activated only when powered ON)"
"Emergency mode (Bolier operation) (To
be activated only when powered ON)"
Active
Refrigerant address number
Add. 2
Add. 3
Add. 4
Add. 5
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
Slave
Master
(PAC-SIF051B-E)
*2
ON
ON
ON
OFF
: Setting is required
— : NO setting (function is not available)
Add. 6
ON
OFF
OFF
ON
ON
ON
OFF
OFF
Slave *1
(Hydrobox)
ON
OFF
61