7. Main remote controller operation
<Main remote controller Menu Tree>
<Continued from the previous page.>
Initial
Main
Main screen
menu
Menu
Service
Password
protected
<See
*1 For more details, refer to the installation manual of PAC-TH011HT-E.
*2 The SD card setting for multiple outdoor units control should be done after turning the power supply of all FTC units (Master/ Slave) ON.
If "COMPLETE!" does not appear, it means the operation is not properly completed. Reset the whole system before re-try.
Manual operation
Function settings
Thermistor adjustment
section>
Auxiliary settings
Heat source setting
Pump speed
Operation settings
Energy monitor
settings
External input settings
Running information
Thermistor reading
Summary of settings
Error history
Password protection
Manual reset
SD card *2
ON/OFF
Economy settings for pump
Delay
ON/OFF
Electric heater (Heating)
Delay
ON/OFF (Booster heater/Immersion heater)
Electric heater (DHW)
Delay
Running
Mixing valve control
Interval
Minimum
Flow sensor
Maximum
Standard (Heat pump & electric heater)/Heater (Electric heater only)/
Boiler/Hybrid (Heat pump & heater/Boiler)
Flow temp.range
Heating
operation
Room temp.control
H/P thermo diff.adjust
Flow t.
Freeze stat function
Outdoor ambient temp.
ON/OFF
Simultaneous operation
Outdoor ambient temp.
ON/OFF
Cold weather function
Outdoor ambient temp.
Hybrid
settings
Boiler settings *1
Intelligent
settings
ON/OFF
Target temp.
Floor dry up function
(
(
For more details,
Flow temp.
refer to Page 45.
(Increase)
Flow temp.
(Decrease)
Booster heater 1
Electric heater
Booster heater 2
capacity
Immersion heater
Pump 1
Water pump input
Pump 2
Pump 3
Delivered energy adjustment
Electric energy meter
Heat meter
Demand control (IN4)
OFF (Heat source)/Boiler
Outdoor thermostat (IN5)
Heater/Boiler
Main remote controller
FTC
SD
Main RC
F1
F2
Main RC
SD
Unrestricted access
Installer only
Shaded items relate
to DHW functions.
These are only avail-
able if the system in-
cludes a DHW tank.
Long press
Min.temp.
Max.temp.
Mode
Interval
ON/OFF
Lower limit
Upper limit
Outdoor ambient temp.
Priority
Ambient/
Cost /CO
2
Electricity
Energy
Boiler
price
Schedule
Electricity
CO
2
Boiler
emission
Heat pump capacity
Boiler efficiency
Heat source
Booster heater 1
capacity
Booster heater 2
capacity
Start & Finish
Max. temp.
Max. temp. period
Temp. increase step
Increase interval
Temp. decrease step
Decrease interval
Yes/No
Yes/No
Select download data
F3
Select upload data
37