En Air Sensors; S Riktningssensorer; En Torques Necessary For The Proper Function Of The Pump; S Moment Som Ska Användas För Säker Funktion Hos Pumpen - Orion 22206 User Manual

Air operated diaphragm pumps
Hide thumbs Also See for 22206:
Table of Contents

Advertisement

En Air sensors

The air sensors are on the inside part of the
diaphragm covers. To access them, follow the
procedure for "replacing diaphragms".
Once the covers are removed follow this
procedure:
1. Remove the two screws holding the air sensor.
2. Remove all components of the sensor, clean
the area.
3. Install the new components in the order
shown.
4. Fit the cover and tighten the screws with a
torque according to the table on page 9.
Remount the remaining components in
reverse order.
EN Torques necessary for the
proper function of the pump
Pump
Diaphragm
cover
3/8"
70,91 lbf in (8Nm)
1/2"
48.7-53.1 lbf in (5,5-6Nm)
1"
137.7 lbf in (15Nm)
Diaphragm pumps_EN_SE_1d
Membrankåpor
Directional
valve
44.25 lbf in (5Nm)
44.25 lbf in (5Nm)
44.25 lbf in (5Nm)

S Riktningssensorer

Riktningssensorerna är placerade på insidan av
membrankåporna. För att komma åt dem följ
anvisningarna i kapitel "Byte av membran".
När kåporna är loss följ instruktionerna nedan:
1. Ta loss de två skruvar som håller sensorerna
på plats.
2. Ta loss alla delar av sensorn och rengör
området de satt i.
3. Montera de nya delarna i den ordning som
visas nedan.
4. Sätt tillbaka kåporna, använd momentnyckel
inställd enligt tabell på sida 9. Montera
återstående delar av pumpen.
S Moment som ska användas för
säker funktion hos pumpen.
Riktnings
Valve cap
ventil
30.9 lbf in(2Nm) composite
35.5 lbf in (4Nm) aluminium
30.9 lbf in(2Nm) composite
35.5 lbf in (4Nm) aluminium
30.9 lbf in(2Nm) composite
Ventil kåpa
11

Advertisement

Table of Contents
loading

Table of Contents