Uniiqa+ family uniiqa+ monochrome line scan simplicity
Table of Contents

Advertisement

Privilege level Management (PrivilegeLevel) : Get the current Camera privilege level.
 Read function (ASCII): "r lock" : Get the current privilege
Returned by the camera : 0 to 2
 Write function (ASCII): "w lock <val>" : <val> is as follow
2 : Lock the Camera in Integrator or "privilege User"
<computed value> : Unlock the Camera back in Integrator mode
There are 3 privilege levels for the camera :
>
Factory (0) : Reserved for the Factory
>
Integrator (1) : Reserved for system integrators
>
User (2) : For all Users.
The Cameras are delivered in Integrator mode. They can be locked in User mode and a specific password is
required to switch back the Camera in Integrator mode. This password can be generated with a specific tool
available from the hotline (hotline-cam@Teledyne-e2v.com)
Camera status : Get the Camera status register (32bits Integer)
 Read function (ASCII): "r stat";
Returned by the camera : 32bits integer :
Bit 0 : (StatusWaitForTrigger) : True if no trig received from more than 1sec
Bit 1 : (StatusTriggerTooFast) : Missing triggers. Trig signal too fast
Bit 2, 3, 4, 5, 6, 7 : Reserved
Bit 8 : (StatusWarningOverflow) : True is an overflow occurs during FFC or Tap balance
processing.
Bit 9 : (StatusWarningUnderflow) : True is an underflow occurs during FFC or Tap balance
processing
Bits, 10, 11, 12, 13, 14, 15 : Reserved
Bit 16 : (StatusErrorHardware) : True if hardware error detected
Bits, 17 to 31 : Reserved