Connector
Pin
1
+24V3
YC8
Connected to
2
MEFSOLN
the MP
solenoid
1
DHEATER
YC9
Connected to
2
+24V1
the drum
heater
1
+24V1
YC10
Connected to
2
FANRN
the power
source fan
motor
1
+3.3V10
YC12
Connected to
2
GND
the eject full
3
PAPFULN
sensor
1
LIFTMOTOR
YC13
Connected to
2
GND
the lift motor
1
+3.3V9
YC14
Connected to
2
GND
the lift sensor
3
LSENS
1
+24V6
YC15
Connected to
2
GND
the polygon
3
PLGDRN
motor
4
PLGRDYN
5
POLCLK
1
+5V5
YC16
Connected to
2
VDATA1P
the APC
3
VDATA1N
PWB
4
VDATA2P
5
VDATA2N
6
SAMPLEN1
7
SAMPLEN2
8
OUTPEN
9
VCONT1
10
VCONT2
11
GND
12
PDN
Signal
I/O
O
24 V DC
O
0/24 V DC
O
0/24 V DC
O
24 V DC
O
24 V DC
O
0/24 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
0/5 V DC
-
-
O
3.3 V DC
-
-
I
0/3.3 V DC
O
24 V DC
-
-
O
0/5 V DC
I
0/3.3 V DC
O
0/3.3 V DC(pulse)
O
5 V DC
O
LVDS
O
LVDS
O
LVDS
O
LVDS
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
Analog
O
Analog
-
-
I
0/3.3 V DC (pulse) Main scanning synchronizing signal
Voltage
24 V DC power output to MPSOL
MPSOL: On/Off
DH: On/Off
24 V DC power output to DH
24 V DC power output to PSFM
PSFM: On/Off
3.3 V DC power output to EFS
Ground
EFS: On/Off
LM: On/Off
Ground
3.3 V DC power output to LS
Ground
LS: On/Off
24 V DC power output to PM
Ground
PM: On/Off
PM ready signal
PM clock signal
5 V DC power output to APCPWB
Video data 1 signal (+)
Video data 1 signal (-)
Video data 2 signal (+)
Video data 2 signal (-)
Sample / hold signal 1
Sample / hold signal 2
Laser enable
LD-1 Light volume adjustment
LD-2 Light volume adjustment
Ground
2-3-9