TECHNICAL DATA BATTERY CHARGER
Voltage range ..........................................................................................
Quick charge current ...............................................................................
Maintaining charge current ......................................................................
Battery charging time with 1.5 Ah ............................................................
Battery charging time with 3.0 Ah ............................................................
Weight according EPTA-Procedure 01/2003 ...........................................
Recommended ambient charging temperature .......................................
WARNING! Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric
shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Do not dispose of used battery packs in the household refuse or by
burning them. Milwaukee Distributors off er to retrieve old batteries
to protect our environment.
Only the following battery packs can be charged with this charger:
Battery Cat.
Cell Type
DC Volts
Capacity
No.
M12B
Li-Ion
12
≤ 1.5 Ah
M12B2
Li-Ion
12
≤ 2.0 Ah
M12B3
Li-Ion
12
≤ 3.0 Ah
M12BX
Li-Ion
12
≤ 3.0 Ah
M12B4
Li-Ion
12
≤ 4.0 Ah
M12B6
Li-Ion
12
≤ 6.0 Ah
M14B
Li-Ion
14.4
≤ 1.5 Ah
M14BX
Li-Ion
14.4
≤ 3.0 Ah
M14B4
Li-Ion
14.4
≤ 4.0 Ah
M18B
Li-Ion
18
≤ 1.5 Ah
M18B2
Li-Ion
18
≤ 2.0 Ah
M18BX
Li-Ion
18
≤ 3.0 Ah
M18B4
Li-Ion
18
≤ 4.0 Ah
M18B5
Li-Ion
18
≤ 5.0 Ah
M18B6
Li-Ion
18
≤ 6.0 Ah
M18B9
Li-Ion
18
≤ 9.0 Ah
Do not try to charge non-rechargeable batteries with this charger.
Do not store the battery pack together with metal objects (short
circuit risk).
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
Never break open battery packs or chargers and store only in dry
rooms. Keep dry at all times.
The battery clamps of the charger are fed by the mains supply. Do
not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new one.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
This appliance is not intended to be
used or cleaned by persons with
reduced physical, sensory or mental
capabilities, or lack of experience or
knowledge, unless they have been
given instructions concerning the safe
use of the appliance by a person
legally responsible for their safety.
They should be supervised whilst
using the appliance. Children shall not
8
ENGLISH
M12-18C
.....12 V, 14,4 V, 18 V
............................3 A
........................500 mA
..........................30 min
..........................60 min
........................704 g
..................... +5...+40 °C
use, clean or play with this appliance,
which when not in use should be
secured out of their reach.
Warning! To reduce the risk of fi re, personal injury, and product
damage due to a short circuit, never immerse your tool, battery
pack or charger in fl uid or al-low a fl uid to fl ow inside them.
Corrosive or conductive fl uids, such as seawater, certain industrial
chemicals, and bleach or bleach containing products, etc., Can
cause a short circuit.
Cell No.
SPECIFIED CONDITIONS OF USE
This charger charges 12V, 14.4V and18V Milwaukee Li-Ion battery
3
packs.
3
Do not use this product in any other way as stated for normal use.
3
2 x 3
MAINS CONNECTION
2 x 3
Connect only to single-phase AC current and only to the system
2 x 3
voltage indicated on the rating plate. It is also possible to connect
to sockets without an earthing contact as the design conforms to
4
safety class II.
2 x 4
2 x 4
CHARGING TIME
5
Battery Cat. No.
Volts
Capacity
5
2 x 5
M12B
12 V
≤ 1.5 Ah
2 x 5
M12B2
12 V
≤ 2.0 Ah
2 x 5
M12B3
12 V
≤ 3.0 Ah
2 x 5
M12BX
12 V
≤ 3.0 Ah
3 x 5
M12B4
12 V
≤ 4.0 Ah
M12B6
12 V
≤ 6.0 Ah
M14B
14,4 V
≤ 1.5 Ah
M14BX
14,4 V
≤ 3.0 Ah
M14B4
14,4 V
≤ 4.0 Ah
M18B
18 V
≤ 1.5 Ah
M18B2
18 V
≤ 2.0 Ah
M18BX
18 V
≤ 3.0 Ah
M18B4
18 V
≤ 4.0 Ah
M18B5
18 V
≤ 5.0 Ah
M18B6
18 V
≤ 6.0 Ah
M18B9
18 V
≤ 9.0 Ah
LI-ION BATTERIES
The rechargeable batteries are partially charged. The LED on the
battery indicates the state of charge.
If it is not used for long periods, the rechargeable battery will
switch to the non-operative state.
When fully discharged the rechargeable battery switches off
automatically (depth discharge not possible).
Under extreme circumstances, the internal temperature of the
battery could become too high. If this happens, the battery will shut
down.
Place the battery on the charger to charge and reset it.
The state of charge can be read by pressing the button on the
rechargeable battery. The battery can be left in the electric tool
while the reading is taken but it must be switched off at least one
minute beforehand (otherwise the display will be inaccurate). The
number of LEDs illuminated indicates the state of charge. A
fl ashing LED indicates a max. power reserve of 10%.
As a general principle, if the electric tool should fail to work after
inserting the rechargeable battery, then the battery should be
plugged into the charger. The displays on the battery and charger
will then provide information about the condition of the battery.
In low temperatures work may continue at reduced output.
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Transportation of those batteries has to be done in accordance
with local, national and international provisions and regulations.
• The user can transport the batteries by road without further
requirements.
• Commercial transport of Lithium-Ion batteries by third parties is
subject to Dangerous Goods regulations. Transport preparation
and transport are exclusively to be carried out by appropriately
trained persons and the process has to be accompanied by
corresponding experts.
When transporting batteries:
• Ensure that battery contact terminals are protected and insulated
to prevent short circuit.
• Ensure that battery pack is secured against movement within
packaging.
• Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice
CHARACTERISTICS
After inserting the battery into the reception of the charger the
battery will automatically be charged (red control lamp is
illuminated continuously)
When a hot or cold battery pack is inserted into the charger
(fl ashing red lamp), charging will begin automatically once the
battery reaches the correct charging temperature (0°C...65°C). The
max. charging current is fl owing when the temperature of the
Li-Ion-battery is between 0°C and 65°C.
Charging Time
The battery's charging time is between 1 min and 30 min (at
max.
1,5 Ah), depending on the state of discharge.
40 min
Once the battery is fully charged, the LED on the charger changes
40 min
from red to green.
72 min
It is not necessary to remove the battery after charging. The
battery can be stored permanently in the charger without the
75 min
danger of being overcharged.
75 min
Under certain circumstances the charger may cause the LED
133 min
indicators to fl ash alternately red and green.
40 min
If this occurs, Remove the battery and reinsert.
75 min
If the LEDs still does not come on, remove pack(s) and unplug
75 min
charger for at least 2 minutes. After 2 minutes, plug charger back
40 min
in and insert pack"
40 min
If both LEDs continue to fl ash, take the charger and battery out of
use immediately for safety reason and have them inspected by a
75 min
Milwaukee customer service center.
75 min
Both 12V and 14.4/18V battery packs can be inserted into the
75 min
charger at the same time, but they will be charged one after the
131 min
other. The fi rst battery pack to be inserted will be the fi rst one to be
191 min
charged. The red LED for the second battery pack will fl ash slowly
to indicate that the charging process has not begun yet.

MAINTENANCE

If the supply cord of this appliance is damaged, it must only be
replaced by a repair shop appointed by the manufacturer, because
special purpose tools are required
Use only Milwaukee accessories and Milwaukee spare parts.
Should components need to be replaced which have not been
described, please contact one of our Milwaukee service agents
(see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the Article No. as well as the machine type printed on the
label and order the drawing at your local service agents or directly
at: Techtronic Industries GmbH, Max-Eyth-Straße 10,
71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before starting
the machine.
Do not burn used battery packs.
Never charge a damaged battery pack.
Replace with a new one.
Do not dispose electric tools, batteries/rechargeable
batteries together with household waste material.
Electric tools and batteries that have reached the end
of their life must be collected separately and returned
to an environmentally compatible recycling facility.
Check with your local authority or retailer for recycling
advice and collection point.
This tool is only suitable for indoor use. Never expose
tool to rain.
Class II tool.
Time-lag fuse 3.15 A
T3.15A
European Conformity Mark
National mark of conformity Ukraine
Regulatory Compliance Mark (RCM). Product meets
applicable regulatory requirements.
EurAsian Conformity Mark.
ENGLISH
9

Advertisement

loading