Sensor Adapters (Option) - Furuno FMD-3200 Installation Manual

Electronic chart display and information system
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

2.3

Sensor Adapters (option)

Maximum eight MC-3000S can be connected to a sensor network (for the redundant
connection: 16). The MC-3000S (serial input/output, IEC61162-2/1, 4ch) can connect
max. 10 sensor adapters using the MC1.5-W cables. The maximum number of MC-
3010A units is five.
When fabricating the MC1.5-W cables, use the lot terminal (ferrule type, supplied) to
maintain performance. This fabrication requires the optional crimping tool (type:
CRIMPFOX 10S). For the relations between the connectors and rod terminals, see
page AP-2. Also, the stickers attached on the reverse side of the covers show the de-
tailed connections.
Attache the cables to the applicable pins.
Pin No.
1
2
3
4
5
Use the ferrule-type terminals (supplied) to connect the cables to the terminals in the
sensor adapters. This connection requires a crimping tool (CRIMPFOX10S, option).
Note 1: Use the MC1.5-W cable between the sensor adapters.
Note 2: The total length of the MC1.5-W cables should be less than 6 m to prevent
malfunction.
How to attach ferrule-type lug
Vinyl sheath
Rod terminal (ferrule type):
After attaching the rod terminal, use the optional
crimping tool CRIMPFOX 10S to crimp.
Cable color
Red
24V_OUT or 24V_IN
Black
24V_GND
White
MODBUS-A
Blue
MODBUS-B
Gray
GND
L
Core
0.5 to 1 mm
Signal
Ferrule-type lug
AI 1.5-6 BK (BLK)
AI 0.34-6 TQ (BLU)
AI 0.75-6 GY (GREY)
AI 1-6 RD (RED)
AI 0.14-8 GY(GREY)
Rod terminal (ferrule type):
The core must protrude 0.5 to 1 mm
past the rod terminal.
2. WIRING
Length of "L"
6 mm
8 mm
2-15