Kyocera ECOSYS P3060dn Service Manual page 82

Hide thumbs Also See for ECOSYS P3060dn:
Table of Contents

Advertisement

Code
Contents
2010
Main motor steady-state
error
Stable OFF is detected for 2 s
continuously after main motor
stabilized.
2200
Drum motor drive error
(60/55/50 ppm model only)
The drum motor is not stabi-
lized within 2 s after driving
starts.
2210
Drum motor steady-state
error
(60/55/50 ppm model only)
Stable OFF is detected for 2 s
continuously after drum motor
stabilized.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Main motor and engine PWB (YC4)
Defective drive
Check if the rollers and gears rotate
transmission sys-
smoothly. If not, grease the bushes and
tem of the main
gears. Check for broken gears and replace if
motor.
any.
Defective main
Replace the main motor.
motor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-22).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Drum motor and engine PWB (YC4)
Defective drive
Check if the rollers and gears rotate
transmission sys-
smoothly. If not, grease the bushes and
tem of the drum
gears. Check for broken gears and replace if
motor.
any.
Defective drum
Replace the drum motor.
motor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-22).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Drum motor and engine PWB (YC4)
Defective drive
Check if the rollers and gears rotate
transmission sys-
smoothly. If not, grease the bushes and
tem of the drum
gears. Check for broken gears and replace if
motor.
any.
Defective drum
Replace the drum motor.
motor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-22).
1-4-14
2T6/2T7/2T8/2T9
Check procedures/
corrective measures

Advertisement

Table of Contents
loading

Table of Contents