Connector
Pin
YC30
1
+3.3V1_F1
Connected to
2
FUPRSTN
the opera-
3
P2C_OK_KEY
tion PWB
4
C2P_BUZCO
N
5
AIRTEMP
6
C2P_LCDCO
N
7
+5V5
8
P2C_SDAT
9
AIRWET
10
C2P_SDAT
11
WETCLK
12
LED
13
FG
14
GND
YC31
1
1WIRE
Connected to
2
+24V3_IL_F5
the relay-L
3
GND
PWB
4
GND
5
+24V0_F3
Signal
I/O
O
3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC
I
Analog
O
0/5 V DC
O
5 V DC
I
0/3.3 V DC
I
Analog
O
0/3.3 V DC
O
0/3.3 V DC (pulse) Humid sensor clock signal
O
0/3.3 V DC
-
-
-
-
-
-
O
24 V DC
-
-
-
-
O
24 V DC
Voltage
3.3 V DC power output to OPPWB
OPPWB reset signal
OK KEY:On/Off
Buzzer control signal
Temperature sensor input signal
LCD: On/Off
5 V DC power output to LCD
Data signal
Humid sensor input signal
The data signal between panel main
READY LED control signal
Ground
Ground
-
24 V DC power output
Ground
Ground
24 V DC power output
2-3-13
2T6/2T7/2T8/2T9