Supermicro X11DPU User Manual page 63

Table of Contents

Advertisement

Memory Fault Indication LEDs
The memory fault LEDs provide visual notification to a service technician which memory
DIMM slot(s) are at fault due to un-correctable memory errors during POST (Power-On Self-
Test). A memory fault LED will remain "on" even after system reboots (or repeated "power
cycling") until it is reset manually by the technician using the BIOS setup menu to turn it off.
This feature allows the technician to easily identify and replace any bad DIMMs that may be
at fault in the system.
Description
LED
LED_P1_A1-A2
Memory Fault LEDs for Memory Module P1_A1-A2
LED_P1_B1-B2
Memory Fault LEDs for Memory Module P1_B1-B2
LED_P1_C1-C2
Memory Fault LEDs for Memory Module P1_C1-C2
LED_P1_D1-D2
Memory Fault LEDs for Memory Module P1_D1-D2
LED_P1_E1-E2
Memory Fault LEDs for Memory Module P1_E1-E2
LED_P1_F1-F2
Memory Fault LEDs for Memory Module P1_F1-F2
LED_P2_A1-A2
Memory Fault LEDs for Memory Module P2_A1-A2
LED_P2_B1-B2
Memory Fault LEDs for Memory Module P2_B1-B2
LED_P2_C1-C2
Memory Fault LEDs for Memory Module P2_C1-C2
LED_P2_D1-D2
Memory Fault LEDs for Memory Module P2_D1-D2
LED_P2_E1-E2
Memory Fault LEDs for Memory Module P2_E1-E2
LED_P2_F1-F2
Memory Fault LEDs for Memory Module P2_F1-F2
VGA
LED1
LEDM1
JTPM1
12 11
10
JF1
CPU2
LEDPWR
JF1
JL1
Memory Fault LED Indicators
IPMI_LAN USB0/1 (3.0)
JUIDB2
COM1
UID
BMC
S-UM12
LAN
JSDCARD1
CTRL
JRK1
BT1
JBT1
PCH
SP1
PSU2
JSD2
JSD1
JHFI1
JNVI2C1
6 5 4
JHFI2
BIOS
DESIGNED IN USA
X11DPU
LICENSE
REV:1.10
BAR CODE
IPMI CODE
7
8
9
FAN5
63
Status
Red: on (memory errors)
Red: on (memory errors)
Red: on (memory errors)
Red: on (memory errors)
Red: on (memory errors)
Red: on (memory errors)
Red: on (memory errors)
Red: on (memory errors)
Red: on (memory errors)
Red: on (memory errors)
Red: on (memory errors)
Red: on (memory errors)
1. LED_P1_A1-A2
2. LED_P1_B1-B2
3. LED_P1_C1-C2
4. LED_P1_D1-D2
5. LED_P1_E1-E2
6. LED_P1_F1-F2
PSU1
7. LED_P2_A1-A2
GPU PWR1
P1_NVMe0 P1_NVMe1
8. LED_P2_B1-B2
1
2
3
9. LED_P2_C1-C2
10. LED_P2_D1-D2
11. LED_P2_E1-E2
CPU1
12. LED_P2_F1-F2
FAN3
FAN2
FAN1
Chapter 2: Installation