Software................ 11 The scope of delivery may vary from product images. This Errors and faults.............. 11 document was created with all due care. Trotec GmbH & Co. KG accepts no liability whatsoever for possible mistakes or Maintenance and repair ............ 11 omissions. Disposal ................ 12...
Trotec. Improper use Do not use the device in potentially explosive atmospheres, for measurements in liquids or at live parts. Trotec accepts no liability for damages resulting from improper use. In such a case, any warranty claims will be voided.
PC by means of the software included in the scope SAVE/CLEAR button of delivery. HOLD/ZERO button Power button P/V/F button MAX/MIN button Unit button Setup / illumination button - input Operating manual – dynamic pressure anemometer TA400...
Indication of the velocity unit Temperature Measuring mode indication Measuring range °C: 0 to 50 °C TEMP indication °F: 32.0 to 122.0 °F Time format indication Resolution °C: 0.1 °F: 0.1 Accuracy °C: ±1.0 °C °F: ±2.0 °F Operating manual – dynamic pressure anemometer TA400...
Scope of delivery Operation • 1 x Dynamic pressure anemometer TA400 Inserting the battery • 1 x 9 V battery Caution! • 1 x Pitot tube Make sure that the surface of the device is dry and the • 1 x Tube, white device is switched off.
Page 7
button (13) to select the desired unit for the measurement. ð The selected unit appears in the pressure unit display (33). 4. Press the HOLD/ZERO button (9) for approx. 2 s to carry out a zero point reset. Operating manual – dynamic pressure anemometer TA400...
Page 8
10° with regard to the air current. than 10° with regard to the air current. ð The measured value will be indicated in the ð The measured value will be indicated in the measurement value display (19). measurement value display (19). Operating manual – dynamic pressure anemometer TA400...
Page 9
ð The REC indication (21) appears on the display. 2. Press the MAX/MIN button (12) to switch between the functions. 3. Press the MAX/MIN button (12) for approx. 2 s to return to the normal measuring mode. Operating manual – dynamic pressure anemometer TA400...
Page 10
3 = measuring modes for air pressure, air velocity and air volume flow Sleep Automatic switch-off for de-/activating the automatic switch-off function Clear memory for clearing the memory; yes or no Operating manual – dynamic pressure anemometer TA400...
Page 11
ð The selected measurement will be deleted. ð An acoustic confirmation signal will be emitted. ð The next saved measurement will be displayed. 4. Press the REC/AVG button (6) for approx. 2 s to return to the measuring mode. Operating manual – dynamic pressure anemometer TA400...
Trotec assumes no liability with regard to this Error code Cause Remedy free software and also provides no support on that score. Trotec air pressure or air velocity • Check the battery voltage and accepts no liability concerning the use of this free software and...
European Parliament and of the Council of 4 July 2012 on waste electrical and electronic equipment (WEEE). At the end of its life, please dispose of this device according to the valid legal requirements. Operating manual – dynamic pressure anemometer TA400...
Page 14
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...