  • Page 1 TA300 INSTRUCTIONS HOT-WIRE ANEMOMETER...
  • Page 2: Table Of Contents

    Dispose of the batteries according to the national regulations. • Remove the batteries from the device if you will not be using the device for a longer period of time. • Never short-circuit the supply terminal in the battery compartment! hot-wire anemometer TA300...
  • Page 3: Personnel Qualification

    The device is not a toy and does not belong in the hands of children. Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications! hot-wire anemometer TA300...
  • Page 4: Device Depiction

    Switching to the previous option/unit Unit  button SETUP/illumination Opening the settings, button switching illumination on or off Designation Mini USB port Charging cable connection Operating elements Telescopic rod Sensor cover Sensor Display Battery compartment Tripod thread Sensor input hot-wire anemometer TA300...
  • Page 5 Averaging calculation is active. Multi-point averaging Multi-point averaging calculation calculation is active. MAX/MIN/REC MAX/MIN: The displayed measured value is the maximum/minimum. REC: The calculation interval is in progress. Lower measurement Indication of various measured value display variables hot-wire anemometer TA300...
  • Page 6: Technical Data

    °F: 0.1 Accuracy °C: ±1.0 °F: ±1.8 Scope of delivery • 1 x Hot-wire anemometer TA300 • 1 x Hot-wire sensor • 1 x Charging cable • 1 x Transport case • 1 x Mini USB cable • 1 x CD-ROM with METER software •...
  • Page 7: Operation

    Wait a few minutes until the device has become adjusted to the changed conditions before carrying out a measurement. ð The air velocity will be displayed in the upper measurement value display (33). ð The temperature value will be displayed in the lower measurement value display (30). hot-wire anemometer TA300...
  • Page 8 2. Press the MAX/MIN button (17) twice to display the lowest 8. In order to return to the normal measurement process, measured value. press the MEAN button (13) once more. 3. Press the MAX/MIN button (17) for approx. 2 seconds to return to the normal measurement process. hot-wire anemometer TA300...
  • Page 9 2. Select "ON" to activate the automatic switch-off function, or "OFF" to deactivate the automatic switch-off function. 3. Confirm the setting by pressing the Enter button (11). ð If the automatic switch-off function is activated, the device switches off after 20 minutes of inactivity. hot-wire anemometer TA300...
  • Page 10: Software

    • Check the battery voltage velocity above the and insert a new high The software is available for download at www.trotec.de. measuring range quality battery for testing Installation requirements purposes.
  • Page 11: Maintenance And Repair

    Do not modify the device or install any spare parts. For repairs also find out about other return options that apply for many or device testing, contact the manufacturer. EU countries on the website https://hub.trotec.com/?id=45090. Otherwise, please contact an official recycling centre for electronic and electrical equipment authorised for your country.