DS6400
2
The following image shows a system consisting of five readers where the Master reader
receives external signals (trigger, serial to host, etc.) and together with Slave 1 and Slave 2
is powered by the C-BOX 100, while Slave 3 and Slave 4 are connected to the power supply
through the PWR-120 and the 610X cable. This is due to the fact the C-BOX 100 can supply
a maximum of 3 readers. This means that the CAB611X cable connects two different groups:
Master, Slave 1, Slave 2 AND Slave 3, Slave 4. It does not propagate power but only
network and synchronization signals.
The cable connecting PWR-120 to Slave 3 is a custom cable with two AWG 20 wires
(VS + GND).
Master
C-BOX 100
CAB600X
CAB610X
BTK6000
Slave 1
P.S.*
CAB610X
BTK6000
Local Host
PWR120
Slave 2
CAB610X
CAB611X
Slave 4
D-SUB 25-pin
Slave 3
*
P.S. (Presence Sensor) connected to External Trigger input.
Figure 67 – Single P.S. with more than 2 Readers and Single Power Unit
42