39) Control panel of the electrically operated main landing gear
(front and rear cockpit)
40) Toggle switch for extension and retraction of the electrically operated main
landing gear
retracted and locked
up
extended
down
41) Press button for retraction of the electrically operated main landing gear
To retract, switch and hold the toggle switch up and press the press button
2 times within 2 seconds.
42) – 44) control lights (LED's) for the electrically operated main landing
gear:
Condition
Normal operation
LG retracted and locked
LG extended and locked
LG retracting
LG extending
LG stopped in intermediate
position
Emergency operation
LG extends
LG extended and locked
System resetting
Failure messages
Time overflow: Signal
appears if within 22
seconds after start of the
travelling no limit switch
activates
One limit switch defective
Note: To save electrical power during flight the upper green LED will stop
shining after approx. 5 minutes if the landing gear is retracted and locked.
Issued: October 2010
Copyright DG Flugzeugbau GmbH - any copy or publishing prohibited
Flight Manual DG-1000M
control light indication
42) upper green shines
44) lower green shines
43) red shines, 42) upper green
blinking
43) red shines, 44) lower green
blinking
43) red shines
43) red shines
44) lower green shines, 43) red shines
44) lower green shines, 43) red shines
43) red blinking + upper or lower green
blinking according to travel direction
all LED's blinking