10. Data Format Commands (P, G, R, W)
10.10 INPUT TYPE ("INPUt") and READING SCALE & OFFSET ("Rd.SC.OF")
TABLE 10.10 INPUT TYPE and READING SCALE & OFFSET
BIT POSITION
7
6
5
4
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
0
1
EXAMPLE: To select 0-100 Volt range input type and enable Reading Scale and Offset :
The command data is 10100011 BIN. = A3 HEX. Then send *W05A3
3
2
1
0
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
INPUt and Rd.SC.OF
TC: J; RTD: 2Pt392 2 wire 100ohm a=392;
Process:+/-50mV, 0-100mV; Current: 0-20mA
TC: K; RTD: 3Pt392 3 wire 100ohm a=392;
Process: +/-500mV, 0-1V; Current: 4-20mA
TC: T; RTD: 4Pt392 4 wire 100ohm a=392;
Process: +/-5V, 0-10V
TC: E; RTD: 2Pt385 2 wire 100ohm a=385;
Process: +/-50V, 0-100V
TC: N; RTD: 3Pt385 3 wire 100ohm a=385
TC: DINJ; RTD: 4Pt385 4 wire 100ohm a=385
TC: R; RTD: 3.LINR 3 wire Linear or Ohms
TC: S; RTD: 4.LINR 4 wire Linear
TC: B
TC
Rtd
VOLt
CURRNt
(Not Used)
bRIdGE
POt
(Not Used)
Rd.SC.OF dISAbL
Rd.SC.OF ENAbLE
10-10