Zero Tracking Range Setting; Accumulation Ending Mode Setting - Excell PCH3 User Manual

Waterproof counting indicator
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.

3-1-7 Zero Tracking Range Setting

Press
key
MC
Enter parameter 00~03
Press
key to
MC
save the setting
 When CFN 01 = 00 ~ 01, the default setting is
When CFN 01 = 00 ~ 04, the default setting is
 After weight keeps stable for over 1 second, it could track  1/4 d.
 After weight keeps stable for over 1 second, it could track  1/2 d.
 After weight keeps stable for over 1 second, it could track  1 d.
 After weight keeps stable for over 1 second, it could track  2 d. (d=division)
 Only when gross = 0, zero tracking function is activated.

3-1-8 Accumulation Ending Mode Setting

Press
key
MC
Enter parameter 00~02
Press
key to
MC
save the setting
Default Setting:
 Press
key. After screen displays accumulation
M+
value for 3 seconds, scale returns to weighing mode.
 Press
key. And screen displays accumulation
M+
value, scale does not return to weighing mode until
pressing
CE
 Press
key. And screen does not display
M+
accumulation value, but beeper beeps once.
03004035
Previous setting
Previous setting
key
.
.
.
 Exit
11
 Move cursor leftward
CE
1
 Move cursor rightward
T
1
 Enter
MC
1
20
ZSME200000058

Advertisement

Table of Contents
loading

Table of Contents