EXCELL PRECISION CO., LTD Table of Contents Special Notice ..........................3 Before Using the Scale........................4 Instructions for Use ......................... 4 Preparing to Use the Scale ......................4 Chapter 1 Introduction ........................6 1-1 Product Features ........................6 1-2 Specifications ........................6 1-3 Product Appearance ......................
Page 3
EXCELL PRECISION CO., LTD 2-3-4 Continuous Transmission Settings ..........31 2-3-5 Selection of the Continuous Transmission Rate ......32 2-3-6 Auto Transmission at Zero ............33 2-3-7 Reset Auto Transmission ............... 34 2-3-8 Output Condition Settings ............. 35 2-3-9 RS232 6/7 Digits Setting ...............
EXCELL PRECISION CO., LTD Special Notice While installing the load cell, power cord hookup or replacing a new rechargeable battery, the indicator housing must be opened. It must be done by a technician assigned by your electronic indicator provider to avoid affecting the waterproof ability of this indicator.
EXCELL PRECISION CO., LTD Thank you for purchasing EXCELL WEIGHING INDICATOR, to help use the product properly, operate smoothly, and extend its life cycle, please read this manual carefully. Before Using the Scale In order to use this scale correctly, we suggest that you read this manual carefully.
Page 6
EXCELL PRECISION CO., LTD Due to the storage battery adopt the advanced free -maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery. 1. The battery should be charged for 8~10 hours.
EXCELL PRECISION CO., LTD Chapter 1 Introduction 1-1 Product Features Sealed to IP68, (Only use cables of 3mm~5mm diameter to ensure correct sealing of the cable glands) Kilogram (kg) and pound (lb) weighing modes Full range tare; Pre-tare; Auto zero tracking; Sampling counting; Gross/Net indication ...
EXCELL PRECISION CO., LTD (RS-232 and load cell cables size 3mm~5.5mm diameter to ensure correct sealing of the cable glands) RS-232 cable entry Load cell cable entry Power supply connector 1-4 Display Description “” indications description : Upper limit : Value between HI and LO 1 : (STABLE) stable indication...
EXCELL PRECISION CO., LTD Low Battery Warning Please note when the ( ) symbol keeps flashing on the display, the internal battery should be recharged. The scale will turn off automatically after a few hours when the low battery warning symbol shows up.
Page 10
EXCELL PRECISION CO., LTD This key is a composite key, while totalization is shown and weight returns to net zero, press M+ key to erase memory. RS232 will output MC print format ( output). If there is new weight added on platter(it is less than 20 divisions in Brazil version, no accumulation ), a new item will be added to totalization.
EXCELL PRECISION CO., LTD 1-7 Self-Test Mode When power is off, hold key and press key, Wait till display shows NET|GROSS ON|ZERO to enter “Self-Test Mode” Press UNIT Press Press ON|ZERO UNIT Press ON|ZERO Press UNIT Press Press ON|ZERO UNIT...
EXCELL PRECISION CO., LTD 1-8 Error Messages The EEPROM is not working correctly. The EEPROM is not set yet, or the circuit on PCB is broken. Zero is higher than the zero range when switching the indicator on.
EXCELL PRECISION CO., LTD Chapter 2 Configurations Configuration Workflow In the weighing mode, press key and key s at the same time to NET|GROSS ON|ZERO enter the configuration mode. The LCD shows Overall workflow of the Advanced Function setting mode:...
EXCELL PRECISION CO., LTD 2-1 General Function Setting Workflow of the General Function setting: Press TA RE|PT key in the parameter “00 ~ 13” ON|ZERO key Upward key (0~ 9 digit ent ry) Key in “00” and press UNIT key Downward key (0~9 digit entry)
EXCELL PRECISION CO., LTD 2-1-1 Auto Backlight Function Setting Select in the general function setting mode to change the backlight function setting. Press TARE |PT LCD displays the last status Default setting = off ON|ZERO UNIT to select function “on” or “off On ...
EXCELL PRECISION CO., LTD 2-1-2 Auto Power-off Timer Setting Select in the general function setting mode to change the automatic power-off timer setting. Press TARE|PT LCD displays the last status Default setting = 0 (No auto power-off) ON|ZERO UNIT Automatic power-off timer setting...
EXCELL PRECISION CO., LTD 2-1-3 HI/LO/OK Settings Select in the general function setting mode to set the HI/LO/OK function. When the high limit and low limit are both set as “0”, the Hi/Lo/OK function is disabled. Press TARE|PT LCD displays the last status...
EXCELL PRECISION CO., LTD 2-1-4 Restore to the Default Settings Select in the general function setting mode to restore to the default settings. Press TARE|PT Return (Cancel the restoration) ON|ZERO UNIT to select “return”or “format” Restore the default...
EXCELL PRECISION CO., LTD 2-1-5 Noise Filter Settings Select in the general function setting mode to set the noise filter settings. Returning to zero point setting LCD displays the last status Returning to the zero point setting Press TARE|PT key to key in the...
EXCELL PRECISION CO., LTD 2-1-6 Hold Function Settings Hold function setting LCD displays the last parameter setting Press TARE|PT Hold function setting key to key in the ON|ZERO UNIT parameters Default setting = 0 0 Hold function disabled...
Page 21
EXCELL PRECISION CO., LTD Hold Function Setting (Animal scale) Hold function setting LCD displays the last parameter setting Press TARE|PT Hold function setting ON|ZERO UNIT key to key in 4 and ON|ZERO UNIT to key in the parameters pPress key to enter the hold TARE|PT function setting mode.
Page 22
EXCELL PRECISION CO., LTD Hold Function Setting (Animal scale) Press Hold function setting TARE|PT LCD displays the last parameter setting ON|ZERO UNIT Hold function setting to key in the parameters keys to key in 5 ON|ZERO UNIT Release Hold range setting...
EXCELL PRECISION CO., LTD 2-1-7 Auto Unit Weight Averaging Setting Auto unit weight averaging setting LCD displays the last parameter setting Press Auto unit weight averaging setting TARE|PT key to key in the ON|ZERO UNIT parameters Default setting = 0 0 ...
EXCELL PRECISION CO., LTD 2-1-9 Foot Switch Settings (Option) Foot switch on “ZERO” function Press TARE|PT Display shows parameter from the previous setup ON|ZERO UNIT Foot switch on “TARE” function to select parameter ON|ZERO UNIT Foot switch on “PRINT” function...
EXCELL PRECISION CO., LTD 2-1-10 F Key Function Settings F key function represents “MC” function Display shows parameter from Press TARE|PT the previous setup F key function represents “HR” function ON|ZERO UNIT To select parameter F key function represents tare or pre-tare value ON|ZERO key ...
EXCELL PRECISION CO., LTD 2-2 External Weight Calibration Press , the display TARE|PT shows the calibration value. The right digit keeps flashing. Press NET|GROSS The calibration value could to move the flashing be changed digit to the left. Press...
EXCELL PRECISION CO., LTD 2-3-1 Baud Rate Settings Select in the RS232 serial interface setting mode to set the Baud Rate. Press TARE|PT Baud rate setting LCD displays the last value Default value: 9600 (bits/sec) ON|ZERO UNIT to select the desired...
EXCELL PRECISION CO., LTD 2-3-2 Communication Protocol Settings Select in the RS232 serial interface setting mode to set the Communication Protocol. Press TARE|PT Communication protocol setting LCD shows the last setting value. Default setting: ON|ZERO UNIT select the protocol setting...
EXCELL PRECISION CO., LTD 2-3-3 Output Format Settings Select in the RS232 serial interface setting mode to set the Output Format. RS232 output format setting LCD shows the last setting. Default setting: Press TARE|PT RS232 output format setting key to select the...
Page 31
EXCELL PRECISION CO., LTD Note1: Ticket No. Date year/month/day & day/month/year (choose 1 out of 2 date formats) Time Total Net (This line will only print when data is erased, showing net weight total of every count) Note2: Ticket No.
EXCELL PRECISION CO., LTD 2-3-4 Continuous Transmission Settings Select in the RS232 serial interface setting mode to set the Continuous Transmission status. Press TARE|PT Transmission setting LCD shows the last setting Default setting: ON|ZERO UNIT to select the transmission...
EXCELL PRECISION CO., LTD 2-3-5 Selection of the Continuous Transmission Rate Select in the RS232 serial interface setting mode to set the Continuous Transmission Rate. Press TARE|PT Continuous transmission rate setting The LCD shows the last setting. Default setting:...
EXCELL PRECISION CO., LTD 2-3-6 Auto Transmission at Zero Select in the RS232 serial interface setting mode to set the Auto Transmission at Zero. Press TARE|PT Auto transmi ssion at zero LCD shows the last setting Default setting: ON|ZERO...
EXCELL PRECISION CO., LTD 2-3-7 Reset Auto Transmission Select in the RS232 serial interface setting mode to Reset Auto Transmission. Press TARE|PT Resetting auto transmission The LCD shows the last setting Default setting: ON|ZERO UNIT to key in the desired...
EXCELL PRECISION CO., LTD 2-3-8 Output Condition Settings Select in the RS232 serial interface setting mode to Reset of Auto Transmission. Press TARE|PT Output condition settings The LCD shows the last setting. Default setting: ON|ZERO UNIT to select the desired setting...
EXCELL PRECISION CO., LTD 2-3-9 RS232 6/7 Digits Setting Select in the RS232 serial interface setting mode to Reset of Auto Transmission. Press TARE|PT Output Condition Restriction Settings Display shows the previous setup Factory Default is (6 places) ON|ZERO...
EXCELL PRECISION CO., LTD 2-3-10 RTC Adjustment Select in the RS232 serial interface setting mode to reset of Auto Transmission. Enter the date in YY/MM/DD Use upward and downward key to select, and use key to confirm TARE|PT Press TARE|PT...
EXCELL PRECISION CO., LTD 2-3-12 RS485 ID Input (Option) Select in the RS232 serial interface setting mode to reset of Auto Transmission. Display shows the previous setup Use upward and downward key to select, and use key to confirm Press...
Page 40
EXCELL PRECISION CO., LTD Command Mode Command Format A Host Command Slave Command Zero Command mode Tare Switch to the first unit Gross weight Switch to the second unit Net weight Switch to the third unit Clear TARE value...
Page 41
EXCELL PRECISION CO., LTD Read weight comparison setting value RS : Groups(00 ~ 09) : Setting Items Show “HI” presetting value Show “LO” presetting value Note : (Group) is various depended on different models 00 The first group 01 The second group 02 ...
Page 42
EXCELL PRECISION CO., LTD Output data format 1. 7 places (first decimal place not included) Weight format Gross 7 SP SP o Tare 6 SP SP k CR LF Plus OL + SP SP SP SP SP SP SP SP SP SP SP SP...
Page 43
EXCELL PRECISION CO., LTD Serial Data Transfer/Receive Format n , 8 , 1 8-bit data STOP e , 7 , 1 7-bit data P STOP o , 7 , 1 7-bit data P STOP Note: : Start bit STOP: Stop bit...
EXCELL PRECISION CO., LTD Appendix 3 Wiring Instructions Load cell wiring method (1) As shown below, when a load cell is connected with a 4PIN cable, SEN+ and SEN- can be unconnected. J11 and J12 on PCB must be tin-soldered in short circuit.
Page 47
EXCELL PRECISION CO., LTD RS232 wiring instruction To connect RS232, please open the housing, RS232’s PIN connectors locate on the bottom-right corner of the main board. The most common connection method is using 9PIN and 25PIN, as shown below: Function...