EXCELL PRECISION CO., LTD.
3-1-5 A/D Sampling Speed Setting
Press
key
MC
Enter parameter 00~01
Press
key to
MC
save the setting
Default Setting:
Low speed is about 7.5 Hz. (Weighing reflection is slow but relatively stable)
Fast speed is about 15 Hz. (Weighing reflection is fast but relatively unstable)
3-1-6 Zero Display Range Setting
Press
key
MC
Enter parameter 00~03
Press
key to
MC
save the setting
When CFN 01 = 00 ~ 01, the default setting is
When CFN 01 = 00 ~ 04, the default setting is
Display all
Zero range 1 bit will not display division, and displays zero instead.
Zero range 2 bit will not display division, and displays zero instead.
Zero range 3 bit will not display division, and displays zero instead.
is set, when setting pre-tare value, it can not be less or equal to 3 bits external value,
If
and so on. When the weight is over 1/3 full capacity and return to 0, this function is activated.
The approval model is disabled.
03004035
Previous setting
Previous setting
.
.
19
Exit
11
Move cursor leftward
CE
1
Move cursor rightward
T
1
Enter
MC
1
ZSME200000058