3-1-3 Stable Range Setting for Quantity Sampling
Press
key
MC
Enter parameter 00~15
Press
key to
MC
save the setting
Default Setting:
While quantity sampling, the scale will indicate a stable reading and error is within 8d
internal value. (d=division)
The higher value makes the sampling faster, but less accurate.
The smaller value makes the sampling slower, but more accurate.
It can't be shifted after sampling, only when the unit weight is cleared in Brazil version.
3-1-4 Auto. Average Unit Weight Setting
Press
key
MC
Enter parameter 00~01
Press
key to
MC
save the setting
Default Setting:
Auto. average unit weight function is off. (Press
calibration)
Auto. average unit weight function is on.
Condition: Auto. unit weight calibration performs when
the measured sampling number increase
greater than 10% but less than 100% of
previous sampling number.
03004035