Troubleshooting/Specifications - Briggs & Stratton 30676 Operator's Manual

Outdoor portable generator
Table of Contents

Advertisement

Available languages

Available languages

Problem
Engine is running, but no AC
output is available.
Engine runs well at no-load but
"bogs down" when loads are
connected.
Engine will not start; starts and
runs rough or shuts down when
running.
For all other issues, see a Briggs & Stratton authorized dealer.
Specifications
Starting Watts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,375
Running Watts* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,500
AC Current at 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29.1 Amps
Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz at 3600 rpm
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Phase
Displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.69 cu. in. (208 cc)
Spark Plug Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.030 in. (0.76 mm)
Fuel Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 U.S. Gallons (18.9 Liters)
Oil Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Ounces (0.6 Liters)
Power Ratings: The gross power rating for individual gasoline engine models is labeled in accordance with SAE (Society of Automotive
Engineers) code J1940 Small Engine Power & Torque Rating Procedure, and is rated in accordance with SAE J1995. Torque values are
derived at 2600 RPM for those engines with "rpm" called out on the label and 3060 RPM for all others; horsepower values are derived at
3600 RPM. The gross power curves can be viewed at www.BRIGGSandSTRATTON.COM. Net power values are taken with exhaust and
air cleaner installed whereas gross power values are collected without these attachments. Actual gross engine power will be higher than
net engine power and is affected by, among other things, ambient operating conditions and engine-to-engine variability. Given the wide
array of products on which engines are placed, the gasoline engine may not develop the rated gross power when used in a given piece of
power equipment. This difference is due to a variety of factors including, but not limited to, the variety of engine components (air cleaner,
exhaust, charging, cooling, carburetor, fuel pump, etc.), application limitations, ambient operating conditions (temperature, humidity,
altitude), and engine-to engine variability. Due to manufacturing and capacity limitations, Briggs & Stratton may substitute an engine of
higher rated power for this engine.
* This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators)
and PGMA (Portable Generator Manufacturers' Association) standard PGMA G200 (Standard for Testing and Validating Performance
of Portable Generators).
Cause
1. One of the circuit breakers is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
1. Generator is overloaded.
1. Engine switch set to off (0) position.
2. Fuel valve is in off (0) position.
3. Low oil level.
4. Dirty air cleaner.
5. Out of fuel.
6. Spark plug wire not connected to
spark plug.
7. Flooded with fuel.

Troubleshooting/Specifications

Correction
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in
good condition.
1. See Generator Capacity.
1. Set switch to on (I) position.
2. Turn fuel valve to on (I) position.
3. Fill crankcase to proper level or
place generator on level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank.
6. Connect wire to spark plug.
7. Wait 5 minutes and re-crank
engine.
15