FX360XL
parallelInG MaCHInes
The FX360XL power sources may be paralleled for increased
output requirements in constant current application. No kit is
required for paralleling of FX360XL power sources. The FX360XL
can only be paralleled for constant current processes. Connect the
power sources as shown, and set the output control of each power
sources to one half of the desired arc current.
Figure A.2
INPUT
TERMINAL
BLOCK
FX360XL
(MACHINE #1)
NEGATIVE
INPUT
TERMINAL
BLOCK
FX360XL
(MACHINE #1)
NEGATIVE
NEGATIVE
AT WORK PIECE
INPUT LINES
W
V
U
TO GROUND
PER NATIONAL
ELECTRICAL CODE
POSITIVE
INPUT LINES
W
V
U
TO GROUND
PER NATIONAL
ELECTRICAL CODE
POSITIVE
POSITIVE
AT WORK PIECE
A-8
INSTALLATION
W
V
U
GND
W
V
U
GND