HP 4200 User Manual page 89

Hide thumbs Also See for 4200:
Table of Contents

Advertisement

2
I select DHCP and
initialization continues.
However, "DHCP No
Reply, Press
continue" appears on the
LCD display.
3
The Power On LED is lit,
but the Network LED does
not light.
4
The Alert LED is lit.
5
I can't locate the appliance
on the network.
6
We had a power outage.
What do I need to do to
recover?
to
For alternative causes/solutions, see
At the time the outage occurred:
Jobs that were spooled but not yet printing may need to be sent
again from the client PC, after the appliance has been normally
powered up again. These jobs should require no action, as they
will print after the appliance is powered up again.
Jobs in the middle of printing will resume printing when the
appliance is powered up again.
Jobs that were not yet spooled need to be resent.
If print operations do not appear normal (new jobs do not spool
correctly) after the outage, then power off the appliance and
power it back up again.
After a power outage or any other improper shutdown, the
The RJ-45 network cables are not connected. Securely
connect the network cables. If the cable is securely
connected, the network LED should blink when their is
traffic on that network segment
A DHCP server could not be found on the network. Verify
DHCP server configuration.
The RJ-45 network cables are not connected. Securely
connect the network cables.
The cable may be faulty. See if another device can
communicate on the network using the same cable.
Verify the hub or switch is connected and is working
properly.
The appliance is not fully booted. Wait for the bootup
process to complete.
A critical defect has been detected. Power cycle the unit to
see if this corrects the problem.
If the Alert LED stays lit, contact HP.
Make sure the appliance is configured with an IP address,
a subnet mask, and a default gateway.
Make sure the Network LED is lit.
The RJ-45 network cables are not connected. Securely
connect the network cables.
A network hub has lost AC power. Re-establish AC power
to the hub.
The appliance is not powered up. Power up the appliance
on and let it boot up.
Client Setup Problems.