MINIMUM CLEARANCES TO COMBUSTIBLES

The clearances listed below are Minimum distances unless otherwise stated:
A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
decorative gas appliance be installed only in accordance with these instructions.
Caution Requirements
The top, back and sides of the decorative gas appliance
are defined by standoffs. The metal ends of the
standoff may NOT be recessed into combustible
construction.
PTO28 Clearance Requirements
Clearance:
A: Back wall
B: Sidewall
C: Ceiling
45" (1143mm)
D
: Floor
1
D
: Floor
2
E: Alcove Width
84"(2134mm)
F: Alcove Depth
72" (1829mm)
Notes:
A
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this decorative gas
appliance be installed only in accordance with these instructions.
Dimension
12" (305mm)
Table Top to back wall
12" (305mm)
Table Top to sidewall
Table Top to Ceiling
0"
When using supplied leveling legs.
1"(25mm)
Unit Base to Floor
Wall to Wall (Minimum)
Front to Back Wall (Maximum)
0"
No Hearth Required
C
B
D
E
F
Alcove
installation
WARNING
Fire hazard is an extreme risk
Measured From:
Regency PTO28-1 City Table Outdoor Gas Fireplace
|