MAINTENANCE INSTRUCTIONS

1. Always turn off the gas supply before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing
and vacuuming at least once a year. When cleaning the logs, use a soft clean paint brush as the logs are fragile and easily damaged.
2. Clean off leaves etc. before burning.
3. Clean appliance with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a outdoor decorative gas
appliance glass cleaner.
4. Hand and finger marks should be cleaned off with a soft cloth and a stainless steel cleaner. Most stainless steel cleaners leave a film/
residue on the surface of the panels. Use an ammonia based cleaner (ie. glass cleaner) to remove this film before applying heat to the unit.
Failure to do this will result in burn stains on panels which you will be unable to remove.
5. Make a periodic check of burner for proper position and condition. Visually check the flame of the burner periodically, making sure the flames are
steady; not lifting or floating. If there is a problem, call a qualified service person.
6. The appliance must be inspected before use, and at least annually, by a qualified field service person, to ensure that the flow of combustion and ventilation
air is not obstructed.
7. Do not use this appliance if the valve and/or electronic components have been or are submerged under water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the control system and any gas control which has been under water. This is not covered under the
terms of the warranty policy.
8. Verify operation after servicing.

THERMOCOUPLE REPLACEMENT

Turn the unit and gas off - allow to cool to room temperature.
Remove cover, glass crystals, rocks or logs, if installed.
1. Remove inner tray by removing 4 screws in locations shown below in
Diagram 1.
Inner tray
2. Remove front nut securing thermocouple in place.
Maneuver thermocouple up out of slot, then push down into the unit.
Remove nut
Diagram 1
Thermocouple
Diagram 2
3. Remove panel (see instructions in Gas Connection in this manual).
Loosen nut to release thermocouple.
4. Replace thermocouple - apply silicone to seal where thermocouple comes
through the burner tray.
Diagram 4 - correct
thermocouple position
5. Reverse steps 3 and 1 to reassemble unit.
Regency PTO28-1 City Table Outdoor Gas Fireplace
maintenance
Loosen nut
Thermocouple
Diagram 3
1/4"
|