Copy Of Safety Decal - Regency Plateau Owners And Installation Manual

Table of Contents

Advertisement

safety decal
|
4
This is a copy of the label that accompanies each PTO28 City Table Outdoor decorative gas appliance. We have printed a copy of the contents here for your
review.
NOTE: Regency
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
®

COPY OF SAFETY DECAL

Listed: OUTDOOR DECORATIVE GAS APPLIANCE /
Certified for/Certifi e pour: CANADA and U.S.A.
é
Conforms to: ANSI Z21.97-2012
Certified to: CSA 2.41-2012 and CGA 2.17-M91(2009)
4001172
NATURAL GAS: Model PTO28CIT-NG1
Maximum supply pressure
14"
WC/C.E. (3.49 kPa)
Minimum supply pressure
5"
WC/C.E. (1.25 kPa)
Manifold pressure high
3.5"
WC/C.E. (0.87 kPa)
Manifold pressure low
0.5"
WC/C.E. (0.12 kPa)
Orifice size
# 32
DMS
Maximum input
33,500 Btu/h
(9.82 kW)
Minimum input
13,000 Btu/h
(3.80 kW)
Altitude
0-4500
ft/pi
(0-1372 m)
The installation must conform with local codes or, in the absence of local codes, with CAN/CSA-B149.1, Natural Gas and Propane Installation Code or ANSI Z223.1/NFPA 54. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the Canadian Electrical Code, CSA C22.1 or with the National Electrical Code, ANSI/NFPA 70. This appliance is only for use with the type of gas indicated on the rating plate . See owner's manual for details.
L'installation doit être conforme aux codes locaux ou, en l'absence de codes locaux, avec CAN/CSA-B149.1, gaz naturel et du propane ou du Code d'installation au ANSI Z223.1/NFPA 54.
L'appareil, une fois installé, doit être connecté électriquement à la terre conformément aux codes locaux ou, en l'absence de codes locaux, avec le Code canadien de l'électricité, CSA C22.1 ou avec le National Electrical Code, ANSI / NFPA 70.
Cet appareil est à utiliser uniquement avec le type de gaz indiqué sur la plaque signalétique. Voir le manuel du propriétaire pour les détails.
FOR OUTDOOR USE ONLY / POUR USAGE EXTÉRIEUR SEULEMENT
IF STORED INDOORS, DETACH AND LEAVE CYLINDER OUTDOORS / SI VOUS LE GARDER À L'INTÉRIEUR, DETACHER LE CYLINDRE ET LAISSER À L'EXTÉRIEUR
For the State of Massachusetts, installation and
repair must be done by a plumber or gas fitter
licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connec-
tors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
4
|
Regency PTO28-1 City Table Outdoor Gas Fireplace
EXTÉRIEUR DÉCORATIFS APPAREIL À GAZ
APPAREIL FONCTIONNANT AU NATURAL GAS
PROPANE GAS: Model
PTO28CIT-NG1
CONCU POUR ETRE POELE: Mod le
é
Maximum supply pressure
Pression d'allimentation maximum
Minimum supply pressure
Pression d'allimentation minimum
Manifold pressure high
Pression à la tubulure d' chappement lev e
é
é
é
Manifold pressure low
Pression à la tubulure d' chappement
é
basse
Orifice size
Grandeur de l'injecteur
Maximum input
D bit Calorifique maximum selon
é
Minimum input
D bit Calorifique minimum selon
é
Altitude
l'altitude
Part #:
919-327
Continue with Serial # series DO NOT start at 0
Printer:
(previous 919-211)
Colour:
Black on grey except what is indicated as being printed red.
Size:
(File at 100%)12.525"x 2.7"
Material:
2 ml silver matt polyester (DPM SMS)
Dec. 11/13:
Created draft for approval - Do not print
Jan. 15/14:
Added ànd CGA 2.17 as per R/D
Feb.20/14:
Updated Standard wording as per R/D
430
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
PTO28CIT
-LP1
É
QUIP A L'UISINE POUR GAZ PROPANE
É
CONCU POUR ETRE POELE: Mod le
Pression d'allimentation maximum
14"
WC/C.E. (3.49 kPa)
12"
WC/C.E. (2.99 kPa)
Pression d'allimentation minimum
11"
WC/C.E. (2.74 kPa)
Pression à la tubulure d' chappement lev e
1"
WC/C.E. (0.25 kPa)
Pression à la tubulure d' chappement
# 50
DMS
Grandeur de l'injecteur
35,000 Btu/h
(10.26 kW)
D bit Calorifique maximum selon
é
11,000 Btu/h
(3.23 kW)
D bit Calorifique minimum selon
é
0-4500
ft/pi
(0-1372 m)
l'altitude
.
NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC DES COMBUSTIBLES SOLIDE.
Duplicate S/N
430
Serial No./ No de serie
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
C
PTO28CIT-LP1
é
B
A
é
é
é
é
basse
D
Made in Canada/ Fabrique au Canada
FPI Fireplace Products International Ltd.
6988 Venture St.
Delta, BC, Canada V4G 1H4
/
Back Wall
A
12" (305mm)
Side Wall
B
12" (305mm)
Ceiling
C
45" (1143mm)
Unit Base
D
1" (25mm)
PTO28CIT-NG1
PTO28CIT-LP1