3.8.1
Intel RAID Adapter RMSP3WD080E Electrical, Thermal and Atmospheric
Requirements.
List of operating conditions for the Intel® RAID adapter RMSP3HD080E:
Power Supply voltage at the 12V rail (from PCI edge connector): 12V ± 8 percent.
Power Supply voltage at the 3.3V rail (from PCI edge connector): 13.3V ± 9 percent.
Relative humidity range is 20 percent to 80 percent non-condensing
Temperature range: 10 °C to +55 °C (with or without the RMFBU module attached)
List of non-operating conditions (while in storage or in transit) for the Intel® RAID adapter
RMSP3HD080E:
Relative humidity range is 5 percent to 90 percent non-condensing.
Temperature range: –40°C to +70°C without battery backup unit
3.8.2

Intel RAID Adapter RMSP3WD080E Consumption.

The following table describes the power consumption of the Intel® RAID adapter RSP3TD160F
under the following states:
State 1: While sitting idle at the DOS prompt or the EFI shell.
State 2: During a drive stress test; average over 20 minutes of sustained operation
Power Mode
3.3V Supply
+ 12 Supply
3.3V Auxillary Supply
Total Power
27
State 1
Typical
1.6W
8.26W
0.03W
9.89W
State 2
Typical
1.6W
8.42W
0.03W
10.05W
RMFBU learn