Fig. 2-17 Cabling To The Shelter; Fig. 2-16 Cabling Of Sideband Antenna - Thales DVOR 432 Technical Manual

Doppler vhf omnidirectional radio range for aiprorts
Table of Contents

Advertisement

DVOR 432
Installation
The supply cables should be fed through the pipes mounted below the counterpoise to the center,
and from there via the U-girder and the cable box to the shelter (Fig. 2-8, 2-17). Excessive lengths
of cable are cleared in a cable box at the lower end of the U-girder. Up to 4 supply cables can be
combined and fed through a single pipe. The RF cabling of the individual sideband antennas to the
shelter should be installed such that, for example, the cable from the central connection of the match
er/decoupling module (Fig. 2-15) of antenna 2 is fed to terminal 2 of the coaxial wall entrance of the
shelter. When the cables are connected, the matcher/decoupling module is screwed to the antenna
terminal via the long installation hole in the vertical pipe (Fig. 2-16). When the screw connections
have been made, the installation hole in the vertical pipe should be closed by raising the cover. Relieve
the cables underneath the vertical pipe using UV-resistant cable ties. When the cables have been
pulled through the pipes below the counterpoise, their ends should be sealed using the packaging
material for the antenna sections, otherwise birds may attempt to nest in the pipes.
The supply cables at the shelter should be laid such that they form a sufficiently large loop to prevent
any rainwater running down the cables and coming into contact with the coaxial screw connections
in the wall entrance. The cable loops should be protected by means of a suitable cover.
1
Matcher/Decoupling-Module
1a Side connectors, decoupling module only
2
Vertical pipe
3
Stuctural steel matting
4
Pipe
5
Cable tie, UV-resistant
6
Coupling cables, used with decoupling module only
Fig. 2-16
Cabling of sideband antenna
É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É
É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É
Counterpoise
Ladder
Ladder foundation
É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É
É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É É
Fig. 2-17
Cabling to the shelter
2-12
RF cable pipe
Cable pipe support
Earth's surface
Cable box foundation
Operation and Maintenance
É É
É É
É É
É É
1a
É
É
É
É
É
É
É É
É É
6
É É É É É
É
É
5
RF cable
cover
U-girder
RF cable box
RF cables
DVOR center
1
1a
2
4
3
Shelter
Shelter foundation
Ed. 01.04