Operation and Maintenance
2.3
DVOR CONTAINER SHELTER
2.3.1
General
See Fig. 2-4.
The Navaids equipment can be supplied already installed in a 10 ft Standard Shelter (type 1D) which
is offered by Thales ATM. To cover the requirements the shelter is based on the definition on transport
containers ISO/DIN standards. The shelter consists of a self-supporting, distortion resistant steel
frame construction with eight ISO corners and walls made of sandwich panels in standardized con
tainer dimensions.
During installation, the shelter should be placed on the foundations such that the door is oriented
according to the site survey and project drawings. The shelter is anchored to the four foundation
blocks using the ISO corners and twist locks. The power supply (mains) and signal (RC, field monitor)
feeder cables enter from below through openings in the shelter floor.
2991
Fig. 2-4
10 ft DVOR container shelter
2.3.2
Transportation and Installation of the Container Shelter
See Fig. 2-5.
When transporting by crane or helicopter, care should be taken to ensure that the angle between the
lifting harness and the crate is at least 60°.
Fig. 2-5
Correct lifting with a lifting harness
Ed. 01.04
(Dimensions in mm; T are weight approx. 900 kg)
2438
min. 60°
DVOR 432
Installation
Support for A/C
Lead through used
for DVOR antenna
connections
2-5