First Switching On - Thales DVOR 432 Technical Manual

Doppler vhf omnidirectional radio range for aiprorts
Table of Contents

Advertisement

Operation and Maintenance
4.2

FIRST SWITCHING ON

4.2.1
Status of the System
- Mains off
- Battery fuse switches open (used for emergency battery, battery fuse box, shelter)
- POWER-switches on BCPS (ACC modules, transmitter cabinet) in position OFF
- PMM: switches NAV, TX1, TX2 (transmitter cabinet) in position OFF
4.2.1.1
Special Jumper Settings before Start Up
Individual jumpers have to be set before the first switching on. These are concerned with the enabling
of backup batteries for non volatile memory (LCP , MSP-VD/1,2, MSG-C/1,2) and the emergency
battery management (CSL). The location of jumpers is shown in section 6.2.4:
- LCP: Set jumper X36 (enabling backup battery for RTC).
- MSP-VD (MSP-D): Set jumper X7 on both boards (enabling backup battery).
- MSG-C: Set jumper X7 on both boards (enabling backup battery).
- CSL: Set jumper X18 (enabling cutoff for over discharge protection of emergency battery).
- CSL: Set jumper X22 (enabling automatic restore).
- CSL: Select minimal battery voltage with jumper X19,20,21 for standard over discharge protection.
4.2.2
Switching On
a) Connect PC serial interface connector (e.g. COM1) to connector Local PC on top of the cabinet
using an interface cable (zero modem cable).
b) Switch on mains and set POWER-switches of BCPS (ACC modules, cabinet) to position ON.
c) Close battery fuse switches (battery fuse box, inside shelter).
d) Set switches TX1/TX2 on PMM (cabinet, front side) to position ON.
e) Set main switch NAV on PMM (cabinet, front side) to position ON. During initialization of the LCP
a buzzer signal is set.
f) Switch to local control with the key-lock switch on the Local Control Interface (LCI).
4.2.3
Preparing the Installation SITE with PC and ADRACS
a) Switch on the PC and run Windows operating system.
NOTE:
Installation and use of the PC User Program is described in the Technical Manual
ADRACS (chapter 1, sect. 1.4 Installation, chapter 2, Functions), more details on set up
of NAV installation is given in section 1.5 of ADRACS manual. It is recommended to be
come familiar with the menus of ADRACS before performing the first set up procedure.
b) Click Start button, select Programs, program group Adracs Remote Controlling, program Adracs
Remote Controlling Software. The 'Adracs - Select Configuration' window appears.
c) Click on configuration type 'STANDARD' or on predefined configuration type and confirm with OK
button. The Main Status window of ADRACS appears.
Ed. 01.04
DVOR 432
Installation
4-5

Advertisement

Table of Contents
loading

Table of Contents