Annex Nextfield
Operation and Maintenance
4.8
SETTING OF MONITOR ALARM LIMITS
4.8.1
Monitor 1
4.8.1.1
Azimuth
a)
Choose azimuth value 'M1 Azimuth'.
(equal to azimuth value of monitor dipole 1).
b)
Upper limit: Add 1.0° to 'M1 Azimuth' reading and key in this value.
c)
Lower limit: Subtract 1.0° from 'M1 Azimuth' reading and key in
this value.
NOTE:
Range of values: 0...359.9;
If during flight check azimuth of transmitters has to be changed,
these azimuth alarm limits have to be readjusted.
4.8.1.2
RF-Level
a)
Upper limit, e.g. 123 %.
b)
Lower limit, e.g. 71 %.
NOTE:
Range of values: Upper Limit 100...150, Lower Limit 50...100.
4.8.1.3
30 Hz AM Signal
a)
Upper limit, e.g. 34.5 %.
b)
Lower limit, e.g. 25.5 %.
NOTE:
Range of values: 0...39.9.
4.8.1.4
9960 Hz Signal
a)
Upper limit, e.g. 34.5 %.
b)
Lower limit, e.g. 25.5 %.
NOTE:
Range of values: 0...39.9.
4.8.1.5
30 Hz FM Signal
a)
Upper limit, e.g. 18.4.
b)
Lower limit, e.g. 13.6.
NOTE:
Range of values: 0...39.9.
Ed. 01.04
INSTRUCTION
DVOR 432
Alignment Procedure
Menu/
C: Commands
A: Activities
Submenu
A/AL1
Alarm Limits M1
A/AL1
M1 Azimuth Upper
Limit ---,- °
A/AL1
M1 Azimuth Lower
Limit ---,- °
A/AL1
M1 RF Level Upper
Limit --- %
A/AL1
M1 RF Level Lower
Limit --- %
A/AL1
M1 Mod. Depth 30 Hz
AM UL --,- %
A/AL1
M1 Mod. Depth 30 Hz
AM LL --,- %
A/AL1
M1 Mod. Depth 9960
Hz AM UL --,- %
A/AL1
M1 Mod. Depth 9960
Hz AM LL --,- %
A/AL1
M1 Mod. Index 30 Hz
FM UL --,-
A/AL1
M1 Mod. Index 30 Hz
FM LL --,-
AN-27